Quick Details
- Allowable range:AC 220V±10% AC110V±10%
- AC current output:6*0-30A or 3 * 0-60A
- Maximum output power:520VA/phase,70VA/phase
- Maximum current output:0-180A
- DC current output:0-300V or 6*0-±130V
- Binary input:1-20mA, 24V (DC)
- Binary output:250V/0.5A (DC)
- Time measurement:0.1ms-999999.999s
- Processing Time:7 days
- Port:Tianjin
- Supply Ability: 5000 Sets Per Month
- Brand Name:GFUVE
- Model Number:Test630
- Place of Origin:China
- Brand Name:GFUVE
Six Phase Current Universal Relay Tester Set /Relay Protection Testing Instrument
Photos
Product Description
FEATURES
Integration in the host crystal 8.4 inches true color,
light weight and easy to carry.
Built-in high-speed and high-performance industrial
computer embedded operating system, running stable and reliable, also can test by connecting PC.
Panel embedded user-friendly buttons, and the panel can
also be an external keyboard and mouse.
High-precision DAC to 12 Road, simultaneously output to
ensure the high precision and good linearity of the waveform.
5Matching electromagnetic compatibility components, can
improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test.
Analog output of the front panel, switch the amount of
terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance.
The latest thermal structure design to ensure the best
ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up
promptly.
Using voltage, current amplifier AC / DC sharing, output
stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current.
12 analog ports and other optional auxiliary DC source
output (220V/110V).
Interface: RJ45 (Ethernet interface), USB interface
(software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use).
OVERVIEW
Six-channel current output
Six-channel voltage output
Eight pairs of binary input
Four pairs of binary output
FUNCTIONS
Host real-time operating system, fast response, when
faced with an emergency situation, can better protect the instruments and equipment under test. Safe and reliable, not easy to be violated by a computer virus.
The newly designed software interface style, the host
machine operation is fully consistent with the background and easy to use.
Extensive testing capabilities: the state sequence will
be determined to meet the needs of various types of user for testing microprocessor-based protection relay in the trial, IT features analog oscillation, the entire group of tests,
differential protection, harmonic superposition, low cycle load shedding, same equipment, measuring instruments, GPS synchronized debugging, fault playback, and custom test (special tests),
etc. It can easily complete the protective device test of ABB, Siemens, AREVA and other foreign manufacturers.
The test report can be easily derived from the USB port
to print.
TEST ITEM
U/I Test
DC Test
Impedance Characteristics
Power Direction Test
I-T Test
Differential Relay
Harmonic Test
Differential Protection
Distance Protection
Zero Sequence Protection
Setting Group Test
State Sequence
Synchronization Test
Special Test
Oscillation Test
Metering Instrument
Hardware Checkout
Low Voltage Protection
Fault Recurrence
PARAMETERS
Electrical parameters
Allowable range
AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement
0.1ms-999999.999s
AC current output
Phase current output (effective value)
6×0-30A or 3 × 0-60A
Maximum output power
520VA/phase
Maximum parallel current output (effective value)
0-180A
Long-term allowable working value of phase current (effective value)
>10A
Allowable working time of maximum current
>11s
Accuracy
<±0.2%
AC voltage output
Phase voltage output (effective value)
6×0-130V
Line voltage output (effective value)
0-260V
Maximum output power
70VA/phase
Accuracy
<±0.2%
DC voltage output
Output range
0-300V or 6×0-±130V
Maximum output power
130VA
Accuracy
<±0.2%
DC current output
Output range
-10-10A or 6×0-±10A
Maximum output power
150VA
Accuracy
<±0.2%
Binary input
Idle contact
1-20mA, 24V (DC)
Electric potential contact
0-250V (DC)
Binary output
Idle contact
250V/0.5A (DC)
Rated output
Frequency error
<±0.01HzHz
Phase error
<±0. 2°
Waveform distortion
<±0.3% (fundamental wave)
Time error
<40µs
Output frequency
0-1050Hz
Superposed harmonic wave
0-21times
Time measurement
Test range
0.1ms-999999.999s
Mechanical parameters
Dimensions (L×W×H) (mm)
360×195×365
Weight (kg)
16.6
Environmental conditions
Use range
0°C to 45°C
Storage range
-25°C to 70°C