GFUVE Kwh Meter Calibration Test Bench GF302D Portable Three Phase Energy Meter Calibrtaion

FOB Price: USD 18000 - 21000
|
1 Sets (Min. Order)
  • Supplying Ability5000 Sets Per Week
  • Supplying TypeOem service
  • Model NumberGF302D
  • Preferred Payment Method:T/T, L/C, Western Union, PayPal

GFUVE electronics company

China

Port: Tianjin

Quick Details

  • AC Voltage Output:57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional)
  • AC Current Output:200mA, 1A, 5A, 20A, 100A
  • Frequency Output:45Hz-65Hz
  • Harmonic:2-51times
  • Dimensions (W*D*H) (mm):500*600*175
  • Weight:27kg
  • Processing Time:7 days
  • Port:Tianjin
  • Supply Ability: 5000 Sets Per Week
  • Brand Name:GFUVE
    GFUVE Kwh Meter Calibration Test Bench GF302D Portable Three Phase Energy Meter Calibrtaion Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three phase, according to relative regulation of kWh meter. Able to do change test caused by voltage influence, frequency influence and harmonic influence. Output of power source is speedy and stable, AC maximum output of each phase can reach 120A in maximum. Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of power source. Frequency of each impulse input port can reach 40Hz. 7-inch TFT color display touch screen, English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button. Each meter position can provide one standard, dependent RS485 port, and able to perform multi-function test, such as communication test. Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.   PARAMETERS Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability <0.01%/120s Distortion ≤0.3% (Non-capacitive load) Output load 45VA Accuracy 0.05%RG Power Output  Active power output stability <0.01%RG/120s Reactive power output stability <0.02%RG/120s Active power measuring accuracy  0.05%RG Reactive power measuring accuracy 0.1%RG Phase Output  Output adjustment range 0°-359.999° Output adjustment fineness 10, 1, 0.1, 0.01 as optional. Resolution 0.01° Accuracy 0.05° Power Factor Adjustment range -1 ~ 0 ~ 1 Resolution 0.0001 Measurement accuracy 0. 0005 Frequency Output  Adjustment range 45Hz-65Hz Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. Resolution 0.001Hz Accuracy 0.005Hz Voltage /Current/Harmonic Setting Harmonic number 2-51times Harmonic content 0-40% Harmonic phase 0-359.99 Harmonic setting accuracy (10%±0.1%)RD(2) Power Energy Measurement Error Active power energy 0.05%RG Reactive power energy 0.1%RG Power Pulse Output  Power pulse type active pulse, reactive pulse Active power pulse output  5V,  10mA Power Pulse Input Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 180K. Mechanical parameters Dimensions (W×D×H) (mm) 500x600x175 Weight (kg) About 27 (1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.