8BK81_12(KYN18A12)_SIEMENS_switchgear

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 15 to 60 days
  • Min Order: 1

Quick Details

Rated voltage 7.2/12kV
Rated power-frequency withstand voltage(1 min) 32/42kV

Supplier Info.

  • Employees Total 501-1000
  • Annual Revenue US$50 Million - US$100 Million

SIEMENS 8BK81 Series Metal-Clad Withdrawable Switchgear, licensed to Zhebao Electrical

SUMMARY

8BK81(KYN18-12)metal-clad Withdrawable switchgear is suitable for 3-se AC 50Hz, 7.2~12kV single busbar and single busbar section system.Apply to distribute electricity power and implement system control,protection and supervision monitoring.The switchgear complies with the standards IEC298,GB3906,DL404.

OPERATIONAL CONDITIONS

Ambient temperature: +40℃ to -10℃.Altitude: 1000m(max).Relative humidity: daily average less than 95%,monthly less than 90%.Shock of earthquake: less than 8 magnitude.This product should not be used under conditions of fire,explosion,earthquake and chemicalcorrosion environments.Note: Special condition and requirement, consult with the manufacturer.

CHARACTERISTIC

All switching operations take place with high-voltage compartment doors closed.Electrical switch position indication on panel front for circuit-breaker,earthing switch and truck position.Logical interlocks prevent maloperation.Positively driven shutters protect against accidental with live parts.Standard degree of protection IP4X against electric shock and ingress of solid foreign bodies.Operating levers can only be inserted when the interlocking conditions are fulfilled.In this way,undue stress on the interlock mechanisms is avoided.The following operations can only take place when the stated interlock conditions are fulfilled:Move the withdrawable part from the test position to the service position-High-voltage compartment door closed-VCB or VC in the OPEN position-(Make-proof)earthing switch in the OPEN positionMove the withdrawable part from the service position to the test position-VCB or VC in the OPEN positionOperate the VCB or VC-Withdrawable part have been locked in the test position or the service position.Operate the(make-proof)earthing switch-Withdrawable part have been locked in the test position.-Cable compartment door closedOpening the high-voltage compartment doorWithdrawable part have been locked in the test position.