Overview

EM-5 series flue gas analyzer is a series of self-developed gas analysis products for onanalysis of domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment ontoring, industrial process control, safety monitoring and etc.

Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.

UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrogra(including the diaagm, a holograc grating, ray detector) and other optical components.

Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and to-voltaic conversion, the gas absorption spectrum is obtained.

The corresponding component concentration in the gas can be calculated by analyzing the spectrum.

Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white structure.

Features Of EM-5 onanalyzer High measurement accuracy

Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)

Ultraviolet has no moisture absorption, undisturbed by moisture and dust

No cross interference between measured gases ( refer to table 1)

Measure NO and NO2 simultaneously without converter

Low detection limit

Measuring gas

Interference

SO2

NO

NO2

O2

SO2 (500ppm)

/

<1ppm

no

no

NO (500ppm)

no

/

no

no

NO2 (500ppm)

no

<1ppm

/

no

H2O (no dew)

no

no

no

no

CO (1000ppm)

no

no

no

no

CO2 (20%)

no

no

no

no

O2 (21%)

no

no

no

/

High reliability

Small zero drift and span drift

Modular design

No optical moving parts, without vibration influence

Strong gas chamber, low cost

Automatic adjustment spectrum technology, long maintenance-free period

Adopt pulse light source with 10-year service life

Technical Parameter Of EM-5 Flue Gas Analyzer

Measurement Principle

UV-DOAS+PLS

Versions

Regular range

Low range

Ultra-low range

Ranges

My range

Max range

My range

Max range

My range

Max range

Component

SO2

0-300ppm

0-3000ppm

0-100ppm

0-300ppm

0-50ppm

0-100ppm

NO

0-300ppm

0-3000ppm

0-100ppm

0-300ppm

0-50ppm

0-100ppm

NO2

0-500ppm

0-4000pp

0-300ppm

0-1000ppm

0-100ppm

0-200ppm

O2 (ECD or ZrO2)

0-5%

0-25%

0-5%

0-25%

0-5%

0-25%

≤±3%F.S.

Repeatability

≤2%

Zero Drift

≤ ± 2% FS / 7d

Span Drift

≤ ± 2% FS / 7d

Response Time(T90)

≤50s

Working Temperature

-20 ℃ ~ + 50 ℃

Preheating Time

No preheating

20min

40min

Sample Gas Interface

Φ6 Bi-Lok

Sample Gas Flow

Range: (0.5 ~ 2) L / min, fluctuation < 25%

Sample Gas Pressure

Current ambient pressure ±0.1Bar

Sample Gas Temp.

0 ℃ ~ + 50 ℃

Sample Gas Humidity

No condensation (under sample gas temperature)

4-20mA Input

3 , configurable, 100Ω load

4-20mA Output

5, output content can be configured, maximum load capacity ≤800Ω

Switching value Input

6 , configurable

Relay Output

14, output content can be configured. DC30V2A

Digital I / O

1×Rs232, 1×Rs485 (Support Modbus protocol)

Installation Method

19’ panel

Supply Voltage

220VAC ± 10%

Rated Power

About 100W

About 120W

Application Of EM-5 Flue Gas Analyzer

Coal-fired power plantCement plantIndustrial furnaceDeSOX process monitoringDeNOX process monitoringWaste incineration plantPVC process in chlor-alkali plantTitanium dioxide production processSulfur recovery processNatural gas purification processMethyl iodide analysis for the coal chemical industry On-monitoring

Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please us!

Premium Services
Need Suppliers
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok