Description electromagnetic flow meter
Electromagnetic flowmeter can only measure the flow of conductive liquid, gas, oil and most organic liquid is not the case of conductive liquids
Detailed Images electromagnetic flow meter
Specification electromagnetic flow meter
Technical Performance Parameters | |||
Caliver | DN3~DN3000mm | ||
Nominal Pressure | 0.6~4.0MPa(special pressure can be made to) | ||
Accuracy | 0.5%,0.3%or0.2% are selectable | ||
erial | Teflon,PFA,F46,Neoprene,Polyurethane | ||
Electrode Type | General type ,scraper type and replaceable type | ||
Electrode material | Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,Stainless steel covered with tungsten carbide | ||
Mediem temperature | Integrate type | -20C~+60C | |
Remote type | Neoprene & Polyurethane an> | -10C~+80C | |
PTFE A 6 an> | -10C~+160C | ||
Ambient Temperature | -25C ~+ 60C | ||
Ambient Humidity | 5~100%RH(relative humidity) | ||
Medium Electrical conductivity | 20 s/cm | ||
Measuring Range | 1500:1,flow rate<15m/s | ||
Structure type | Integral type,remote type,submersible type,ex-proof type | ||
Protection Class | IP65,IP68(optional) | ||
Ex-proof Mark | ExmII T4 | ||
Product Standard | JB/T 9248-1999 Electormagnetic Flowmeter |
Main performances of the electrode materials | |
Electrode material | Applications |
ainless steel SUS316 | Applicable in water,sewage and corrosive mediums. Widely used in industries of petrol,chemistry,carbamide,etc |
Stainless steel covered with tungsten carbide | Applicable in mediums of no corrosive and low abrasion. |
Hastelloy B(HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont.Also resistable against vitriol,ste, hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt. |
Hastelloy C(HC) | Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as Fe+++,Cu++aStnd sea water |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc. Not resistant to a pure reducing acid(such as sulric acid,hydrochloric acid corrosion. But if acid contains antioxidant is greatly reduce corrosion. |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass Almost is applicable to all chemical mediums. Except for hydrofluoric acid,oleum and alkali. |
Platinum-iridium | Almost be applicable in all chemical mediums except for ammonium salt. |
Features
1. The measurement can not be influenced by the change of fluid density,viscosity,temperature,pressure and conductivity;
2.The inside of measuring tube do not have the parts to block the flow move,no pressure loss,low demand in straight pipe;
3.Totally deal with digital quantity, high anti-interference,reliable measurement,high precision,flow range reach to 1500:1;
4.Converter adopts to 16-bit embedded microprocessor and surface mounting technology,convenient preferences,totally chinese menu operation,easily use,with self-check and diagnosis functions;
5.With the function of measuring two way flow,can show the positive and reverse flow,also have two way current and rate output,which is convenient for the record and store different flow p> 6. Inside have three counters,which can separately show positive cumulation,reverse cumulation and D-value calculation; 7.With RS485 or RS232 digital communication span> 8.With self-check and diagnosis functions. Selection Guide electromagnetic flow meter Transmitter diameter usually used with the piping system and the same caliber. If the orbital system is to be designed, the caliber can be selected based on the flow range and flow rate. For electromagnetic flowmeter, the flow rate of 2-4m / s is more appropriate. In special cases, such as liquid with solid particles, taking into account the wear and tear, optional common flow rate ≤ 3m / s, for easily attached to the wall of the fluid flow rate can be used ≤ 2m / s, the flow rate is determined, To determine the transmitter diameter. Transmitter range can be based on two principles to choose: First, the instrument full scale is greater than the maximum expected maximum value of the flow, and second, the normal flow of more than 50% of the full scale to ensure a certain measurement accuracy. 2. Preliminary selection (1) According to the learned name and nature of the measured medium to determine whether to use electromagnetic flowmeter Note: Electromagnetic flowmeter can only measure the flow of conductive liquid, gas, oil and most organic liquid is not the case of conductive liquids (2) According to the understanding of the nature of the medium, to determine the electrode material Note; the company generally provides stainless steel, Hastelloy, titanium and tantalum four kinds of electrodes, the choice of which electrode should be based on the nature of the media check the relevant information manual (2) According to the temperature of the medium to determine the use of rubber or PTFE lining (determined by the salesman) Note: rubber temperature shall not exceed 80C; PTFE temperature 150C, an instant resistance to 180C; Urban sewage can generally be rubber- stainless steel electrodes (3) According to the learned media pressure, select the form body flange specifications (determined by the salesman) Note: The specifications of the electromagnetic flange is usually when the diameter from DN10-250, the flange rated pressure ≤1.6Mpa; When the diameter from DN250-1000, the flange rated pressure ≤ 1.0Mpa; When the actual medium pressure is higher than the above diameter - pressure corresponding range, for special orders, but the maximum pressure shall not exceed 6.4Mpa (4) Determine the conductivity of the medium Note: (1) Electromagnetic flowmeter conductivity of not less than 5uS / cm (2) tap water conductivity of about dozens to hundreds of uS / cm, general boiler soft water (deionized water) conductive, pure water (highly distilled water) is not conductive (3) The conductivity of gases, oils and most organic liquids is much lower than 5uS / cm and is not electrically conductive. Company Information electromagnetic flow meter