Tidal volume(Vt) 50~1200ml
Application Operating Room and ward
Ventilation Mode: SIPPV,IPPV,PSIMV,CPAP,PCV,PEEP,SIGH,SPONT,SIMV
Power Source Electric
Type Breathing Apparatus
PEEP 0-10cmH2O
Air Compressor 220V AC±10%, 50±1Hz, 700VA
Respiratory Rate 1-99bpm
(I:E) Ratio 4:1-1:4

Supplier Info.

  • Employees Total 11-50
  • Annual Revenue US$1 Million - US$2.5 Million

Specifications

Model: 900B (Advanced Model)

Display: 10.4 inch high visibility color TFT display

Ventilation Mode: A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT, MANUAL

Minute Volume: Greater than or equal to 18L

Back-up Power Suppl:y At least 4 hours

Tidal Volume Adjustable range: 10-1500ml, Display range: 0-2000ml

Respiratory Rate:Â 1-99bpm

Inspiratory/expiratory (I:E) ratio: 4:1-1:4

PEEP: 0-10cmH2OÂ

SIMV Rate: 1-20bpm

Inspiratory Pressure Trigger : .-10-10cmH2OÂ

Trigger Sensitivity (flow): 1-10L/m

Inspiratory Plateau: Adjustable from 0-50% of inspiratory time

Adjustable Oxygen Concentration: 21-100%

Gas Supply Requirement: 280~600 kPa medical grade oxygen and compressed air supplyÂ

Pressure Limit: 1.0kPa~6.0kPa

Maximum Safe Operating Pressure: ≤6.0kPa

Tidal Volume Alarm: Upper Limit: 10~2000ml, Lower Limit: 0~1800ml

Airway Pressure Alarm: Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa

Oxygen Concentration Alarm:Â Upper Limit: 22~100%, Lower Limit: 21~80%

Â

Model700B (Advanced Model)
Display10.4 inch high visibility color TFT display
Ventilation ModeA/C, SIPPV, IPPV, SIMV, PSIMV, PEEP, SPONT MANUAL
Minute VolumeGreater than or equal to 18L
Back-up Power SupplyAt least 4 hours
Tidal VolumeAdjustable range:Â 50-1500ml, Display range: 0-2000ml
Respiratory Rate1-99bpm
Inspiratory/expiratory (I:E) ratio4:1-1:4
PEEP0-10cmH2OÂ
SIMV Rate1-20bpm
Inspiratory Pressure Trigger-10-10cmH2OÂ
Trigger Sensitivity (flow)1-10L/m
Inspiratory PlateauAdjustable from 0-50% of inspiratory time
Adjustable Oxygen Concentration21-100%
Gas Supply Requirement280~600 kPa medical grade oxygen and compressed air supply
Pressure Limit1.0kPa~6.0kPa
Maximum Safe Operating Pressure≤6.0kPa
Tidal Volume AlarmUpper Limit: 10~2000ml, Lower Limit: 0~1800ml
Airway Pressure AlarmUpper Limit: 0.1~6kPa, Lower Limit: 0~5kPa
Oxygen Concentration AlarmUpper Limit: 22~100%, Lower Limit: 21~80%