Medical Anesthesia machine equipment for selling

  • Origin: China
  • Supply Type: in stock
  • Processing Time: within 3-5 working days
  • Min Order: 1

Quick Details

Ventilation modes: P-CMV, V-CMV, P-SIMV, V-SIMV, PSV, SIGH, MANUAL
Warranty 12 months
Certificate CE&ISO
Tidal volume(Vt) 0, 20 mL ~ 1500 mL
Frequence(Freq) 1bpm ~ 100 bpm
I/E 4:1~1:8
PEEP 0cmH2O ~ 30 cmH2O
Display 12.1″ TFT LCD touch screen

Supplier Info.

  • Employees Total 11-50
  • Annual Revenue US$1 Million - US$2.5 Million

Features

Â

  • Electronic flowmeter

High precision flowmeter, instantly know the fresh gas flow to patient.

O2 and N2O linkage device ensure O2 concentration no less than 25%.

Â

  • 12.1″ TFT LCD touch screen

Displays the Ventilation parameters, Alarm information and Oscillogram.

High sensitivity touch screen ensures accurate and easy operation. Alternate button for dual control.

Technical specifications

Ventilation modes:P-CMV, V-CMV, P-SIMV, V-SIMV, PSV, SIGH, MANUAL
Ventilator parameter rangesÂ
Flow meterO2(0.1-10L/min)
 N2O(0.1-10L/min)
 AIR(0.1-10L/min)
Rapid oxygen supply35L/min-75L/min
Tidal volume(Vt)0, 20 mLÂ ~Â 1500 mL
Frequence(Freq)1bpm ~ 100 bpm
I/E4:1~1:8
PEEP0cmH2OÂ ~Â 30 cmH2O
Pressure triggering sensitivity(PTr)-20 cmH2OÂ ~Â 0 cmH2O(Based on PEEP)
Flow trigger sensitivity (FTr)0.5 L/min ~ 30 L/min

Pressure control (PC)

5 cmH2OÂ ~Â 60 cmH2O
SIGH0(off)Â 1/100Â ~Â 5/100
Apnea VentilationOFF,5 s ~ 60 s
Pressure Limit20 cmH2OÂ ~Â 100 cmH2O
Monitored ParametersÂ
Frequence(Freq)0 /min ~ 100 /min
Tidal volume(Vt)0 mLÂ ~Â 2000 mL
MV0 L/min ~ 100 L/min
Oxygen concentration15 %Â ~Â 100 %

Â

Gracal display:Â
P-T(pressure – time)Â
F-T(flow – time)Â
P-V loop (pressure – volume loop)Â
V-T(volume – time )Â
Â

Alarm and protectionÂ

The AC power failure alarmPower failure or no connection
Internal battery backup low voltage alarm<11.3±0.3V
No tidal volume≤5Ml within 6s
High oxygen concentration alarm

Low oxygen concentration alarm

19%-100%

18%-99%

Suffocation warning5s-60s no spontaneous ventilation
The maximum limited pressure <12.5 kPa
Fan error

Oxygen deficit

Â

Show on screen

Show on screen

Working conditionsÂ
Gas sourceO2,N2O,AIR
Pressure280kPa-600kPa
Voltage100-240V
Power frequency50/60Hz
Input power80VA
VaporizerHalothane, Enflurane, Isoflurane, Sevoflurane
Premium Services
Tell us your Requirement
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok