    Diesel Generator Set Data

    Set Type: XG-220GF

    Standby Power: 220KW/275KVA

    Prime Power: 200KW/250KVA

    Rated Current: 360 (A)

    Rated Frequency: 50(Hz)

    Start-up time: 5~6(s)

    Power Factor: 0.8(Lag)

    Rated Voltage: 400/230(V)

    Standard Features

    1. Engine: CCEC NT855-GA

    2. Radiator 50℃ max

    3. Fans are driven by belt, with safety guard

    4. 24V charge alternator

    5. Dry type air filter, fuel filter, oil filter

    6. Alternator: single bearing alternator

    7. IP23, insulation class H/H

    8. Main uit breaker

    9. Standard control panel

    10. Absorber

    11. Muffler

    12. User manual

    Diesel Engine Data
    Manufacturer:CCEC Cummins
    Model:NT855-GA
    Prime/Standby Power:231KW/264KW
    Rated Speed:1500(r/min)
    Cycle:4 stroke
    Cylinder Arrangement:6 in
    Displacement:10.8L
    Bore and Stroke:125*147(mm)
    Compression Ratio:15:1
    Governor Type:Electronic
    Start battery voltage:24V DC
    Air Intake System
    Air Intake System:Turbo, Water/Air Cooling
    Max Intake Restriction:6.2kPa
    Burning Capacity:19.3m3/min
    Air Flow:490m3/min
    Exhaust System
    Exhaust Gas Flow:57m3/min
    Exhaust Temperature:470℃
    Max Back Pressure:10kPa
    Fuel System
    Fuel System:PT type fuel pump
    100%( Prime Power) Load:203g/kwh
    50%( Prime Power) Load:218g/kwh
    Oil System
    Total Oil Capacity:27.6L
    Oil Consumption:≤0.4g/kwh
    Engine Oil Tank Capacity:24L
    Oil Pressure at Rated RPM:276-414kPa
    Cooling System
    Cooling Way:Water-cooled
    Total Coolant Capacity:61L
    Thermostat:82-93℃
    Max Water Temperature:104℃
    Alternator Data
    Manufacturer:STARLIGHT/STAMFORD/SIEMENS/MARATHON/ENGGA /KEPU
    Excitation Mode:Brushless and self- exciting
    of se and Access Act:3-se 4-
    Connecting Type:"Y" type connecting
    Alternator Capacity:250KVA
    Alternator Efficiencies:95ï¼…
    Overload:(PRP)110% load can run 1h
    Protection Level:IP22-IP23
    Insulation Class, Temperature Rise:H/H
    TeleInfluence Factor (TIF):<50
    THF:<2%
    Voltage Regulation, Steady State:≤±1%
    Air Cooling Flow:0.58m3/s
    Altitude:≤1000m
    Genset Electrical Performance
    Voltage Regulation:≥±5%
    Voltage Regulation, Stead State:≤±1%
    Sudden Voltage Warp (100% Sudden Reduce):≤+25%
    Sudden Voltage Warp (Sudden Increase):≤-20%
    Voltage Stable Time (100% Sudden Reduce):≤6S
    Voltage Stable Time (Sudden Increase):≤6S
    Frequency Regulation, Stead State:≤5%
    Frequency Waving:≤1.5%
    Sudden Frequency Warp (100% SuddenReduce):≤+12%
    Sudden Frequency Warp (Sudden Increase):≤-10%
    FrequencyRecoveryTime(100%SuddenReduce):≤5S
    FrequencyRecoveryTime(Sudden Increase):≤5S

    Options

    Engine

    Alternator

    Heater 2KW & 4KW

    Anti Condensation Heater

    Battery Charger 3.5A & 7A

    Permanent Magnet Generator(PMG)

    Water Separator

    Drop CT(For Paralleling)

    Daily Fuel Tank

    Fuel Level Sensor

    Control System

    Others

    Remote Control Panel

    Rainproof Type

    Auto Transfer Switch (ATS)

    Soundproof Type

    Paralleling System

    Trailer Type

    Open Type

    Overall Size

    Weight

    3000(mm)*1020(mm)*1750(mm)

    2600(kg)

    Cummins 200GF

    Soundproof Type

    Overall Size

    Weight

    4400(mm)*1800(mm)*1680(mm)

    3650(kg)

    Cummins 200GFg

    Standard Control Panel

    Cummins 200GF

    Starlight Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability

    Auto Module Control Panel

    Cummins 200GF

    Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output and realize auto start and stop of generators. 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation. 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect ATS and control directly.

    Auto Parallel Control Panel

    This new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the periral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future.