Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor

1. Product: Stator testing machine

2. Tested product: compressor motor stator

3. Stator testing machine introduction

This testing machine can be used to test the stator of compressor motor for home appliance. The AC Hipot/high voltage/dielectric strength, insulation resistance, surge/impulse/layer short, winding resistance and direction of rotation can be tested at one-stop.

The testing machine comes with two test stations to ensure the efficiency of the production. All the tests mentioned above takes less than 8 second in total for one stator. Standard equipped with the three color alarm light to indicate the machine status.

4. Technical specification

4.1 Hipot/high voltage/dielectric strength

output voltage setting range/precisionAC 500~5000V ±(1.5%×setting value+10V)
Leakage current testing range/precision0.10~30.00mA ±(2%×display value+0.05mA)
Hipot current presetting alarm rangeMax: 0.10~30.00mA; Min: 0.00~30.00mA
Hipot current/resolution±(2%×display value+0.05 mA);0.01 mA
test time range/resolution0.5~999.9s 0.1s/step
arc detection0~9 grade

4.2 Insulation resistance

output voltage setting range/precisionDC 500V/1000V ±(1.5%×display value+10V)
insulation resistance testing range/precision

1~500MΩ

≤100MΩ:±(3%×display value+0.5MΩ);

>100 MΩ:±(5%×display value+5MΩ)

insulation resistance alarm setting rangeMax: 0~500MΩ; Min: 1~100MΩ
test time range/resolution0.5~999s 0.1s/step

4.3 Surge

output voltage setting range/precision500~5000V ±(3%×display value+10V)
sampling frequency100MHz
waveform comparison

area, area difference, corona, se

three waveforms will be displayed on the testing interface

4.4 DC winding resistance

measuring range and precision10.0mΩ~2000Ω ±(0.3%×display value+3 words) temperature compensation can be set
test time range/resolution

0.5~20s 0.1s/step

temperature compensationYes
temperature probe/measuring rangeDS18b20 -10.0℃~+50.0℃
precision±0.5°C(range: -10℃~+50℃)

4.5 Direction of rotation

RotationCW/CCW/Still