Color | Customized |
Model Description
AGR: Tinned copper, Silicone Rubber Insulated
AFRP:Tinned copper, Silicone Rubber Insulated Shielding
Specification And Construction Data
Conductor Size mm² | Conductor Construction Roots/mm | Root's maximum mm | Insulation Thicknessmm | mm | Conductor Electric Resistance 20âΩ.m | Testing kv | Weight | |
Thinnest | Average | |||||||
0.30 | 12/0.18 | 0.21 | 0.44 | 0.60 | 1.9±0.05 | 53.1 | 3 | 6.0 |
0.50 | 28/0.15 | 0.21 | 0.44 | 0.60 | 2.2±0.05 | 40.1 | 3 | 9.0 |
| 20/0.18 | 0.21 | 0.44 | 0.60 |
| 40.1 | 3 |
|
0.75 | 30/0.18 | 0.21 | 0.44 | 0.60 | 2.4±0.10 | 26.0 | 3 | 12 |
| 24/0.20 | 0.21 | 0.44 | 0.60 |
| 26.0 | 3 |
|
1.0 | 32/0.20 | 0.21 | 0.44 | 0.60 | 2.5±0.10 | 19.5 | 3 | 14.5 |
1.50 | 30/0.25 | 0.26 | 0.53 | 0.70 | 2.9±0.10 | 13.3 | 5 | 20 |
2.00 | 40/0.25 | 0.26 | 0.53 | 0.70 | 3.10±0.10 | 10.0 | 5 | 24.5 |
2.50 | 49/0.25 | 0.26 | 0.62 | 0.80 | 3.78±0.10 | 7.98 | 5 | 29.5 |
4.0 | 56/0.30 | 0.31 | 0.62 | 0.80 | 4.2±0.10 | 4.95 | 6 | 47 |
6.0 | 84/0.30 | 0.31 | 0.62 | 0.80 | 5.0±0.10 | 3.3 | 6 | 65 |
10.0 | 84/0.40 | 0.41 | 0.8 | 1.0 | 6.98±0.10 | 1.91 | 6 | 125 |
16.0 | 126/0.40 | 0.41 | 0.8 | 1.2 | 8.00±0.10 | 1.21 | 6 | 175 |
16.0 | 84/0.50 | 0.51 | 0.8 | 1.2 | 8.00±0.10 | 1.2 | 6 | 175 |
25 | 196/0.40 | 0.41 | 0.8 | 1.2 | 10.4 | 1.08 | 6 | 26 |
35 | 280/0.40 | 0.41 | 0.8 | 1.4 | 12.6 | 1.0 | 6 | 37 |
50 | 399/0.40 | 0.40 | 0.8 | 1.6 | 14.5 | 0.8 | 6 | 55 |
Order Information
1ãThe length of ring is not less than 20 meter. Delivery of short segments with a length of not less than 10 meters is aviable and the percent is not over 10%. Delivery may also be made at any length in accordance with the agreement.
2ãConductor materials and constructions, such as nickel plated or nickel plated, may be made according to the agreement.
3ãThere are red, black, yellow, blue, green, white, brown, orange, purple, gray, transparent and translucent colors for election.