Product name | Anesthesia Machine |
Certificate | CE ISO 13485 |
Feature | Durable |
OEM | Avalibale |
GAS Source | O2 and N2O |
Function | Emerfgency Care |
Usage | Operation Theatre |
Type | Anesthesia Equipments & Accessories |
Ventilation Mode | IPPV, A/C, SIMV, SIGH, MANUAL |
Product Description
item | value |
Place of Origin | China |
Jiangsu | |
Brand Name | Superstar |
Model /div> | S6100A(Basic) |
Power Source | Electricity |
Warranty | 1 Year |
After-sale Service | Onnical support |
Material | Acrylic, Metal, Plastic, Steel |
Shelf Life | 1years |
Quality Certification | ce |
Instrument classification | Class II |
Product name | Anesthesia Machine |
Feature | Durable |
OEM | Avalibale |
GAS Source | O2 and N2O |
Function | Emerfgency Care |
Usage | Operation Theatre |
Type | Anesthesia Equipments & Accessories |
Ventilation Mode | IPPV, A/C, SIMV, SIGH, MANUAL |
Ventilation mode | |
IPPV, A/C, SIMV, SIGH, MANUAL | |
Ventilator parameter range | |
Flowmeter | O2 (0.1ï½10 L/min)N2O (0.1ï½10 L/min) |
Rapid oxygen supply | 25 L/minï½75 L/min |
Tidal volume (Vt) | 0, 20 mLï½1500 mL |
Frequence | 1 /minï½100 /min |
I:E | 2:1ï½1:6 |
PEEP | 0 cmH2Oï½30 cmH2O |
Pressure triggering sensitivity (Ptrï¼ | -20 cmH2Oï½0 cmH2O (Based on PEEP) |
Flow trigger sensitivity ï¼Ftrï¼ | 0.5 L/minï½30 L/min |
SIGH | 0 (off) 1/100ï½5/100 |
Apnea ventilation | OFFï¼5sï½60s |
Pressure limit | 20 cmH2Oï½100 cmH2O |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | ï¼11.3±0.3V |
No tidal volume | â¤5mLwithin 6s |
High oxygen concentration alarm | 19%ï½100% |
Low oxygen concentration alarm | 18%ï½99% |
High airway pressure alarm | 20 cmH2Oï½100 cmH2O |
Low airway pressure alarm | 0 cmH2Oï½20 cmH2O |
High minute volume alarm | Adult (5 L/minï½20 L/min) |
Paed (1 L/minï½15 L/min) | |
Low minute volume alarm | 0ï½10 L/min |
Continuous pressure alarm | (PEEP+1.5 kPa) over 16s |
Suffocation warning | 5sï½60s no spontaneous ventilation |
The maximum limited pressure | ï¼12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Monitoring parameter | |
FrequenceTidal volume (Vt)MVOxygen concentration | 0 /minï½100 /min0 mLï½2000 mL0 L/minï½100 L/min15 %ï½100 % |
Working condition | |
Gas sourcePressureVoltagePower frequency | O2, N2O280 kPaï½600 kPa100ï½240V50/60 Hz |
Packing size | |
Wooden case packing sizeG.W.N.W. | L 740* W 800* H 1460mm98KG66KG |
Oscillogram | |
P-T (pressure â time)F-T (flow â time) |