Join today and be a part of the fastest growing B2B Network Join Now

IEC60950 Open Loop Hall Effect Current Sensor High Accuracy Switched Mode Power Supplies

  • Origin: China
  • Supply Type: oem service

Supplier Info.

  • Employees Total 51-100
  • Annual Revenue

Switched Mode Power Supplies Open Loop Hall Effect Current Sensor

TKC-H series is a kind of dismountable current sensor, which is a open loop device based on the measuring principle of the hall effect ,with a galvanic isolation between primary and secondary circuit .It provides accurate electronic measurement of DC,AC or pulsed currents.

Open-loop current sensors measure AC and DC currents and provide electrical isolation between the circuit being measured and the output of the sensor (the primary current is measured without electrical with the primary circuit, providing galvanic isolation).

Standards

  • UL94-V0.
  • EN60947-1:2004
  • IEC60950-1:2001
  • EN50178:1998
  • SJ 20790-2000

Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF)

Type

Parameter

TKC600HTKC1200HTKC1800HTKC2400HTKC3000H

Unit

Rated current(Ipn)

±600±1200±1800±2400±3000A

Measuring range(Ip)

±1200±2400±2700±3600±4500A

Rated output voltage

@Ip=±Ipn ±4±1%V

Supply voltage

±15±5%V

Power Consumption

+25,-10mA

Offset voltage

@Ip=0 ±20mV

Magnetic offset

@Ip=±Ipn-0 ±20mV

Offset voltage drift

@ -40~+85℃ ≤±1mV/℃
output drift@ -40~+85℃ ≤±1mV/℃

@Ip=0-±Ipn ≤1%FS

Response time

@50A/μS, 10%-90% ≤7μS

Galvanic isolation

@ 50HZ,AC,1min 6KV

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

Mechanical dimension(for reference only)

IEC60950 Open Loop Hall Effect Current Sensor High Accuracy Switched Mode Power Supplies 0

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm.

Directions for use

When the current will be measured goes through a sensor, the voltage will be measured at the output end.

(Note: The false wiring may result in the damage of the sensor)

The output amplitude of the sensor can be adjusted according to users’ requirements.

Custom design in the different rated input current and the output voltage are available.

General date

ValueUnitSymbol
Operating temperature-40 to +85ºCTA
Storage temperature-40to +125ºCTS
Mass(approx)602gM

Characteristics chart

Effects of impulse noise

IEC60950 Open Loop Hall Effect Current Sensor High Accuracy Switched Mode Power Supplies 1

Premium Services
Need Buyers
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok