OEM 1500 watt Off Grid pure sine wave inverter 12v 220v with bypass function
It is an easy way to provide access to electricity when camping or for emergency use during a power outage.In addition,it has two USB-2 chargers for , tablets, âs an asset when power is off for an extended period (such as with hurricanes), you have an immediate place to go for charging and medical issues such as nebulizer treatments.
pure sine wave inverter specifications:
MODEL | TFS1500-112 | TFS1500-124 | TFS1500-148 | TFS1500-212 | TFS1500-224 | TFS1500-248 | |
Output | AC Voltage | 100/110/120VAC | 220/230/240VAC | ||||
Rated Power | 1500W | ||||||
Surge Power | Load 120~150%(3min.);3000W(3sec; resistive) | ||||||
Waveform | Pure Sine Wave(THD<3%) | ||||||
Frequency | 50/60Hz ±0.05% | ||||||
AC Regulation | ±5% | ±10% | |||||
Power Factor Allowed | COSθ-90°~COSθ+90° | ||||||
Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | ||||||
LED Indicator | Green for power on, red for faulty status | ||||||
USB port | 5V 2.1A | 5V 2.1A | ------ | 5V 2.1A | 5V 2.1A | ------ | |
LCD display | voltage, power, protection status ( optional) | ||||||
Remote control function | default | ||||||
Remote controller | CR80/CRD80 optional | ||||||
Input | No Load Current Draw | â¤1.1A | â¤0.80A | â¤0.70A | â¤1.1A | â¤0.80A | â¤0.70A |
DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC | |
Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC | |
Efficiency(Typ.) | 89%~93% | ||||||
Fuse | 40AÃ6 | 20AÃ6 | 10AÃ6 | 40AÃ6 | 20AÃ6 | 10AÃ6 | |
Remote Control | Function (optional) | ||||||
Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC |
BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | |
Over Load | Shut down output voltage , restart to recover | ||||||
Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | |
Over Temperature | Shut down output voltage , recover automatically after temperature goes down | ||||||
Output Short | Shut down output voltage , restart to recover | ||||||
DC Input Reverse Polarity | By fuse | ||||||
Earth Fault | Shut off o/p when the load has electrical leakage | ||||||
Soft Start | Yes, 3-5 Seconds | ||||||
Environment | Working Temp. | 0~+50â | |||||
Working Humidity | 20~90%RH non-condensing | ||||||
Storage Temp.&Humidity | -30~+70â,10~95%RH | ||||||
Safety & EMC | Safety Standards | Certified UL 458(only for "GFCI" receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | ||||
Isolation Resistance | I/P-O/P:100M Ohms/500VDC | ||||||
EMI Conduction &Radiation | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | |||||
EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 | |||||
E-MARK | ------ | Certified ECE RIO.05:2014 | |||||
Others | Dimension(LÃWÃH) | 325.2Ã281.3Ã112.7mm | |||||
Packing | 5.2kg;2pcs/11.1kg/0.053m³ | ||||||
Cooling | Load control fan or by thermal control fan | ||||||
Application | Home and Office appliances,Portable Power Equipment, Vehicle,Yacht and Off-Gid Solarpower systemsâ¦etc. |