Pallet PLC Splitter, 19" Rack Mount 1x64 SC / UPC, Used for FTTH
Pallet type fiber optic PLC splitter has no open r optic cable is in a metal box with many high quality optical fiber adapters. According to the quantity of the adapters it mounted, It will be fixed to the fiber optic splice outdoor cabinet or optical distribution frame. The tray type PLC splitter can be inserted into the fiber optic tray directly. It is suitable for various types of optical fiber splitter, wave demultiplexer and other integrated installation and use.
FOC COMMUNICATION CO., LTD provides a various of 1xN and 2xN PLC 1U rack mount type splitters, including 1x2, 1x4, 1x8, 1x16,1x32,1x64 1U rack mount type PLC splitter and 2x2, 2x4, 2x8, 2x16, 2x32, 2x64 1U rack mount type PLC splitters.
FeaturesConfiguration Pallet Type 1x64Fiber Type Single Mode G.657A1Connector Type SC/APC
Low Insertion lossLow PDLHigh Return LossUniform Power SplittingCompact DesignWide Operating WavelengthWide Operating TemperatureExnt Environmental & Mechanical StabilityQualified Under Telcordia GR-1221 and GR-1209
Applications
TelecommunicationsLocal area networkFiber to the homeVideo transmissionFiber optic sensingTesting instrumentsCATV
Optical Specifications
Parameter | Unit | Specification (P Grade) | |||||
Channel /span> |
| 1X2 | 1X4 | 1X8 | 1X16 | 1X32 | 1X64 |
Operation Wavelength | nm | 1260ï½1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.4 | 10.7 | 13.9 | 17.2 | 21.5 |
Uniformity (Max.) | dB | 0.5 | 0.8 | 1.0 | 1.4 | 1.6 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | â¥50 | |||||
Directivity | dB | â¥50 | |||||
Operating Temperature | â | -40ï½+85 | |||||
Storage Temperature | â | -40ï½+85 |
Parameter | Unit | Specification (P Grade) | |||||
Channel /span> |
| 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 |
Operation Wavelength | nm | 1260ï½1650 | |||||
Insertion Loss (Max.) | dB | 4.3 | 7.6 | 11.0 | 14.8 | 17.9 | 21.5 |
Uniformity (Max.) | dB | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
Polarization Dependent Loss | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
Return Loss | dB | â¥50 | |||||
Directivity | dB | â¥50 | |||||
Operating Temperature | â | -40ï½+85 | |||||
Storage Temperature | â | -40ï½+85 |
Note: All the data above does not include connectors. Ordering Information
PLC |
|
|
|
|
|
|
| Port | Fiber Type | Input | Output | Pigtail Length | Connector |
PLC | 0102=1x20104=1x40108=1x80116=1x160132=1x320164=1x640204=2x40208=2x80216=2x160232=2x320264=2x64 | 1=G652D, 2=G657A | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | L=900µm Loose tube, S=2.0mm, R=3.0mm, 0=Adapter | 05-20=0.5--2.0m, 0=Adapter, X=Others | FU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC, LA=LC/APC, 00=None, X=Others |
We can produce many serials of PLC splitters including:1X2, 1X4, 1X8, 1X16, 1X32, 1X64, 2X4, 2X8, 2X16, 2X32, 2X64 with following packageBare fiber seriesMini loose tube packageABS Module typeLGX box typeRack Mount patch panel for PON application.Wall Mount patch panel for PON applicationInr optic splice closure typeErect fiber optic splice closure type