HuaWei NE5000E interface board CR5D00E2NC62 CP400-2x100GBase-CFP2 2-port 100G CFP2 flexible card
Overviews
HW NetEngine5000E Cluster Routers CR5D00E2NC62, 2-Port 100GBase-CFP2 Flexible Card(CP400,Occupy 1 sub-slot).
Specifications
Part /span> | 03030TCG |
Model | CR5D00E2NC62 |
Description | 2-Port 100GBase-CFP2 Flexible Card(CP400,Occupy 1 sub-slot) |
Attributes | Hardware |
Category | |
Product n> | Networking |
Product Family | Router |
Overview | |
Sub Product Family | NetEngine5000E Cluster Routers |
Product Series | NE5000E-X16 |
UOM | PCS |
Net Dimension(D*W*H mm) | 193*178*37mm |
Typic Power(W) | 70.3 |
Board Type | 100G Platform | 400G Platform | 1T Platform |
MPU | MPUB5 (CR5D0MPUB560) | MPUB5 (CR5D0MPUB560) | MPUB6 (CR5D0MPUB660) |
SFU | SFUF100C (CR5DSFUFA06C) | SFUI400A(CR5DSFUIK06A) used for CLCSFUI400B(CR5DSFUIK06B) used for cluster | SFU1TE(CR5DSFUIT06E) used for CLCSFU1TH(CR5DSFUIT06H) used for cluster |
Item | NE5000E Specification |
Dimensions (H x W x D) | (40 U) 1778 mm x 442 mm x 650 mm (70 in. x 17.4 in. x 25.59 in.) (Chassis main body) |
Weight (empty) | 115.7 kg (255.07 lb) (including the backplane, PEM, and PMU and excluding the fan and power module) |
Weight (full configuration) | 100G single-chassis (full configuration): 337 kg (742.96 lb)100G cluster (full configuration): 346 kg (762.80 lb)400G single-chassis (full configuration): 364 kg (802.48 lb)400G cluster (full configuration): 380 kg (837.76 lb)1T single-chassis (full configuration): 384 kg (846.58 lb)1T cluster (full configuration): 405 kg (892.87 lb) |
Cabinet installation standard | Can be installed in an 800 mm-deep standard 19-inch cabinet and is installed in a 2200 mm-high Huawei N68E cabinet by default. |
Typical power consumption | 7300 W (100G single-chassis)7492 W (100G cluster)10000 W (400G single-chassis)11000 W (400G cluster)11000 W (1T single-chassis)13000 W (1T cluster) |
Typical heat dissipation | 23684.3 BTU/hour (100G single-chassis)24307.2 BTU/hour (100G cluster)32444.2 BTU/hour (400G single-chassis)35688.6 BTU/hour (400G cluster)35688.6 BTU/hour (1T single-chassis)42177.5 BTU/hour (1T cluster) |
DC input voltage | input voltage range: -40V to -72Vinput rated voltage: -48V/-60V |
AC input voltage | Voltage range:180Vac~264Vac.220 V rated voltage:200Vac to 240Vac. |
MTBF | 20.14 years |
MTTR | 0.5 hours |
Availability | 0.99999 |
Slot quantity | 22 |
Redundant MPUs | 1:01 |
Redundant Switch fabrics | 3+1 |
Redundant fans | Consists of upper and lower areas.(400G) Two fan modules. If a single fan fails, the system can still work for a short period of time at an ambient temperature of40°C.(1T) Three fan modules. If a single fan fails, the system can still work for a short period of time at an ambient temperature of40°C. |
Redundant power supply | N+N |
Forwarding performance | 10816 Mpps |
Switching capacity | 40.96 Tbps |
Operating temperature | Long-term: 0°C to 40°C (32°F to 104°F)Short-term: -5°C to 50°C (23°F to 122°F)Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h) |
Storage temperature | -40°C to 70°C (-40°F to 158°F) |
Relative operating humidity | Long term: 5% to 85% RH, non-condensingShort term: 5% to 95% RH, non-condensing |
Relative storage humidity | 5% to 95% RH, non-condensing |
Long-term operating altitude | 3000M @ 40°C |
Storage altitude | Less than 5000 m (16404 ft.) |