Item

Technical Index

Specification

Input

Input voltage

1AC/3AC 220V±15%, 3AC 380V±15%, 3AC 660V±15%

Input frequency

47~63Hz

Output

Output voltage

0~rated input voltage

Output frequency

V/f control: 0~3000Hz

Sensorless vector control: 0~300Hz

Control Features

Control mode

V/f control

Sensorless vector control

Torque control

Operation command mode

Keypad control

Terminal control

Serial communication control

Frequency setting mode

Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.

Overload capacity

G model: 150% 60s, 180% 10s, 200% 3s

P model: 120% 60s, 150% 10s, 180% 3s

Starting torque

0.5Hz/150% (SVC); 1Hz/150% (V/f)

Speed adjustment range

1:100 (SVC), 1:50 (V/f)

Speed control precision

±0.5% (SVC)

Carrier frequency

1.0--16.0kHz, automatically adjusted according to temperature and load characteristics

Frequency accuracy

Digital setting: 0.01Hz

Analog setting: maximum frequency * 0.05%

Torque boost

Automatically torque boost; manually torque boost: 0.1%~30.0%

V/f curve

Three types: ultiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)

Acceleration/deceleration mode

Straight rve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s

DC braking

DC braking when starting and stopping

DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~100.0s

Jog operation

Jog operation frequency: 0.0Hz~maximum frequency

Jog acceleration/deceleration time: 0.1s~3600.0s

Simple PLC & multi-step speed operation

It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.

Built-in PID

Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)

Automatic voltage regulation

Keep output voltage constant automatically when input voltage fluctuating

Control Function

Common DC bus

Common DC bus for several inverters, energy balanced automatically

Torque control

Torque control without PG

Torque limit

“Rooter” characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process

Wobble frequency control

Multiple triangular-wave frequency control, special for textile

Timing/length/

counting control

Timing/length/counting control function

Over-voltage & over-current stall control

Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping

Fault protection function

Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default se, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function

Input/output terminals

Input terminals

Programmable DI: 7 on-off inputs, 1 high-speed pulse input

2 programmable AI: AI1: 0~10V or 0/4~20mA

                 A12: 0~10V or 0/4~20mA

Output terminals

1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)

2 relay output

2 analog output: 0/4~20mA or 0~10V

Communication terminals

Offer RS485 communication interface, support MODBUS-RTU communication protocol

Human machine interface

LED display

Display frequency setting, output frequency, output voltage, output

current, etc.

Multifunction key

QUICK/JOG key, can be used as multifunction key

Environ-ment

Ambient temperature

-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).

Humidity

90%RH or less (non-condensing)

Altitude

≤1000M: output rated power, >1000M: output derated

Storage temperature

-20℃~60℃