MIX8411 CO Gas Sensor 2000ppm Carbon Monoxide Sensor

  • Origin: China
  • Supply Type: oem service

Supplier Info.

  • Employees Total 101-200
  • Annual Revenue

Principle Introduction:

MIX8411 is an electrochemical Carbon Monoxide ( CO) sensor developed by Mixsen. It uses the principle of electrochemistry. There is a reference electrode inside the sensor, which greatly improves the stability of the sensors. When the sensor senses the carbon monoxide, the working electrode and the counter electrode react with the redox reaction, through measure the current to get the concentration of CO gas.

Feature:

Low power consumption;High precision;High sensitivity;Wide nge;

Long service lifeTemperature compensationAnti-vapor interferenceGood anti-interference ability;

Environmental protection design

Application:

* Industrial co gas monitors, leakage detection

* Fixed or portable CO gas detector

Technical Parameters :

ItemSpecification
Target GasCarbon Monoxide(CO)
Measurement Range0~1000 ppm
Maximum Overload2000 ppm
Output0.1 ± 0.02 μA/ppm
Repeatability±2%
Response Time(T90)< 20 Seconds
Resolution0.5 ppm
Long Term Output drift<10% per year
Life Expectancy(in air)3 Years
Operating Temperature Range-20 ~ 50ËšC
Operation Press0.1MPa±10%
Operating Humidity Range15% ~ 95% RH, no-condensing
Note: All measurements were taken at 20ËšC, 50%RH at 1013hPa

Operating Note:

* Forbidden tin soldering before usage.* Aging for more than 48 hours before using.* Sensor’s pins can’t be broke off or bent.* Don’t disassemble the sensor to avoid the damage caused by electrolyte leakage.* Avoid ng organic solvent (including silicone rubber and other adhesive), coatings, medicine, oil and high concentration gases.* All the electrochemical sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment, otherwise, it will damage the function of sensor* All electrochemical sensors shall not be applied in corrosive gas environment, or the sensor will be damaged* Zero calibration should be finished in clean air.* During test and usage, sensors should avoid the gas inflow vertically* The side for inflow can’t be choked and polluted.* The laminating film above the sensor surface can’t be uncovered and damage.* Excessive impact or vibration should be avoided* It takes some time for the sensor to return to normal state after it is applied in high concentration gas.* Working electrode and reference electrode of the sensor shall be in short circuit when stored* Prohibit to use the hot cement or sealant of which the curing temperature is higher than 80℃ to make the capsulation for the sensor.* Prohibit storage and usage for long time in alkas with high concentration.* Do not use the sensor when the shell is damaged.