Cooling Chiller Prices
Brief introduction
Cooling chiller is constant flow, constant voltage. Used for purification of high purity metals, rare ent experiment and magnetron sputtering, vacuum coating and other large equipment, and also can meet the cooling demand of electron microscopy, electron probe, ultra high vacuum sputtering apparatus, X~ray machine, laser and accelerate the electric light those high valueequipment. Cryogenic cooling liquid circulating pump is particularly suitable for the chemistry, biology, sics laboratory work under normal conditions or need to maintain a low temperature. It is a necessary lab equipment for medicine, chemical industry, food industry, metallurgical industry, universities, scientific research, genetic engineering, polymer engineering and so on . (Can be customized large capacity according to user needs ).
Product features
(1) Air-cooled and hermetically sealed compressor units (import) with dependable quality;
(2) The dedicated and high~quality relays, protective devices and capacitors of the refrigerating units;(3) Digital Read Out of temperature and microprocessor controller for temperature, simple and easier to see;
(4) It can be matched with a variety of instruments (rotary evaporators, fermentation tanks, chemical reactors, freeze-drying equipments, rmaceutical reactors, etc.);
(5) Bigger cooling capacity and faster cooling speed, which have greatly improved the working efficiency;
(6) All models of this machine can be matched reasonably between the low temperature and the cooling capacity or capacity basing on the requirements of customers.
Technical Parameters
Zhengzhou Keda low-temperature pump types classification
According to the volume of cryogenic cooling bath circulation pump divided into : 5L, 10L, 20L, 30L, 40L, 50L, 60L, 80L,100L.
Each volume according to the lowest temperature can divide into : -10?, -20?, -25?, -30?, -40?, -60?, -80?, -120?.
Model | DLSB-10/10 | DLSB-10/20 | DLSB- 10/25 | DLSB-10/30 | DLSB-10/40 | DLSB-10/60 | DLSB-10/80 | DLSB- 10/120 | |
Refrigerant Performance | Volume | 10 L | |||||||
No Load Min. Temp (?) | -14 | -23 | -28 | -32 | -42 | -62 | -82 | -122 | |
Cooling Capacity (W) | 1894-884 | 2733-813 | 3256- 990 | 2036-1022 | 2628-748 | 3679-510 | 3679-160 | 4997- 120 | |
Circulating Performance | Flow(L/min) | 20 | |||||||
Lift(m) | 4-6m | ||||||||
Temperature Control Performance | Coolant Temp. (?) | -10 | -20 | -25 | -30 | -40 | -60 | -80 | -120 |
Temp. Precision (?) | ±0.2 | ||||||||
Working Condition | Power Supply | 220V/50Hz | 220V/50Hz 380V/50Hz | 380V/50Hz | |||||
Environment Temp (?) | 25 | ||||||||
Environment Humidity | (60-80%) Ventilation | ||||||||
Machine Dimensions | Length (mm) | 500 | 550 | 550 | 580 | 580 | 730 | 880 | 900 |
Width (mm) | 400 | 420 | 420 | 450 | 450 | 660 | 670 | 700 | |
Height (mm) | 650 | 680 | 680 | 680 | 680 | 880 | 900 | 900 |
Precautions:
Please read it carefully before using the instrument.
1, The machine's power standard is 220 v, should be equipped with reasonable grounding system and the safety of the standard three pole socket.
2, Before use , pls put into the liquid medium (water, alcohol, antifreeze can also be), medium level should not lower than cold tube and 20 mm below the workbench is advisable. Don't let sand , acid-base class material or debris into the cooling system or the circulation pump, to prevent clogging or corrosion coil.
3, Recurring observe the slot liquid level height, when the liquid level is too low, should be timely to add liquid medium.
4, When pump working temperature is lower, should pay attention not to open the cover. Never put your hand into the groove, to prevent frostbite.
5, The Pump working environment, temperature less than or equal to 25 ° C , humidity less than or equal to 60 ?, no obstacles in the instrument around 300 mm. Indoor open flame is strictly prohibited.
6, When the liquid outer loop, the client shall pay special attention to the robustness of the out pipe joint, fight off, in order to avoid liquid leakage.
Brief introduction of our company:
Zhengzhou Keda Machinery and Instrument Equipment Co., Ltd. is specialized in R & D, production, sales, teaching and chemical biology rmacy equipment integrated company. The main products are rotary evaporator, jacketed glass reactor, single layer glass reactor, circulating water vacuum pump, low temperature reaction bath (slot), low temperature cooling fluid circulation pump(cool chiller), vacuum drying oven, blast air drying oven, freeze dryer, water/oil bath, magnetic heating stirrer, overhead mixer, ultrasonic cleaning machine, lift platform, etc. Besides, we act as agents of some domestic and foreign famous enterprise products, sustaining high prais in domestic junior colleges and universities, scientific research units, etc. Our products are sold to USA, Australia, Asia, Brazil, Iran, Egypt etc. countries and our customers have been fully affirmation.
Pictures of cooling chiler
Can be macthed with rotary evaporator
Packaging of circulation pump :
After-sale service
1. ZZKD Instruments provides one year warranty for the products described here.
2. The warranty covers part and manufacturing defects. In the case of a part or manufacturing defect, the device shall be repaired or replaced free of charge under the terms of the warranty.
3. Beyond the warranty period, product problems can also be solved by our company, but charge component cost and maintenance cost properly.
4. ZZKD Instruments shall not assume liability for any damages incurred as a result of improper handling.
5. If you encounter problems when using our products, please us by or e-mail, we will be ready to provide consulting, maintenance and other services immediately.