Join today and be a part of the fastest growing B2B Network Join Now

Efficient Multi-Channel Digital Input Ethernet Remote Acquisition Module M410T

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 15 Days

Quick Details

Product name Multi-Channel Digital Input Ethernet Remote Acquisition Module
Sensor Type Wet contact (NPN or PNP), Dry Contact
I/O Mode 1*RJ45+1RS485+16DIN
Counter Frequency 700khz(Only the 1st Channel can be used as high speed pulse counter)
LAN Ethernet 10/100 Mbps, RJ45 por
LAN Protocols TCP, TCP/IP,TCP Server,TCP Client
Serial Port RS485+RJ45
Modbus Slave address Modbus Slave address
Serial Port Protection Serial Port Protection
Dimensions L105 * W88 * H30mm

Supplier Info.

  • Company Name King Pigeon Communication Co., Ltd
  • Membership:Free
  • Business Type: Manufacturer, Trading Company, Buying Office, Agent, Distributor/Wholesaler, Government ministry/Bureau/Commission, Association, Business Service (Transportation, finance, travel, Ads, etc), Other
  • Employees Total
  • Annual Revenue

Efficient Multi-Channel Digital Input Ethernet Remote Acquisition Module M410T

Specifications

Ethernet Remote I/O Module Specifications

• Digital Input

Sensor Type

Wet (NPN or PNP), Dry /span>

I/O Mode

DI or Event Counter

Dry /span>

• On: short to GND=0• Off: open=1

Wet (DI to COM)

• On: 10 to 30 VDC =1• Off: 0 to 3 VDC=0

Counter Frequency

700khz(Only the 1st Channel can be used as high speed pulse counter)

Digital sampling frequency

500Hz

Digital filtering strategy

Continues 3 times

Isolation

Optical Isolated,3k VDC or 2k Vrms

• Digital Output

Type

Sink

I/O Mode

DO

Pulse Output Frequency

10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

Over-Voltage Protection

50 VDC

Over-Temperature Shutdown

175°C (typical), 150°C (min.)

Load Current

Max. 500 mA per channel

Digital sampling frequency

500Hz

• Analog Input

Type

Differential input

Resolution

12 bits

I/O Mode

Voltage / Current (jumper selectable)

Input Range

0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

Accuracy

±0.1% FSR @ 25°C±0.3% FSR @ -10 and 60°C±0.5% FSR @ -40 and 75°C

Sampling frequency

20Hz

Isolation

Electrical isolation

• Working Power Requirements

Input Voltage

12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

12 to 36 VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP,TCP Server,TCP Client

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master or slave.

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

6. High sampling frequency and special filtering strategy to ensure reliability;7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules;8. Supports register mapping function and extend I/O inquiry strategy;9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;12.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

Typically applications:

1. BTS Monitoring;

2. Security Alarm System applications;

3. Supervision and monitoring alarm systems;

4. Automatic monitoring system;

5. Vending Machines security protection;

6. Pumping Stations, Tanks, Oil or Water levels;

7. Buildings and Real Estate;

8. Weather Stations;

9. River Monitoring and Flood Control;

10. Oil and gas pipespan>

11. Corrosion protection

12. Temperatures, water leakage applications;

13. Wellheads, boat, vehicle;

14. Energy saving, street lights control system;

15. Valve controls;

16. Transformer stations;

17. Unmanned machine rooms;

18. Control room application;

19. Automation System, M2M;

20. Access Control System;

21. PLC Gateway, PLC Remote Monitoring.

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok