Join today and be a part of the fastest growing B2B Network Join Now

Three-Three Phase 10KVA-40KVA 60KVA-80KVA Online High Frequency UPS

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 7days

Supplier Info.

  • Employees Total 201-300
  • Annual Revenue Above US$100 Million
  • PRODUCT SPECIFICATION ADVANCED POINTS
  • 1. Large input voltage range: full load: 275Vac-475Vac; no-load:210Vac-475Vac
  • 2. Large input frequency range: The UPS can work in mains INV mode if the input ranges from 40 to 70Hz.
  • 3. High output accuracy: ±1% output voltage error.
  • PRODUCT FEATURES
  • 1. High-frequency one-in and three-out UPS, the output can be connected to unbalanced load, and the input three-se always keeps the load balanced.
  • 2. Fully digital control,more stable performance.
  • 3. Energy-saved and environmental protection, efficiency is up to 93%
  • 4. Support N+X parallel redundancy
  • 5. The most optimized tower structure design has the smallest volume compared to similar products on the market
  • 6. A single set of battery supplies power to the system, reducing the of batteries and save cost.
  • 7. 10-20K standard machine integrated design with battery built-in, easy to install and use.
  • 8. Visualized LCD display interface, clear and intuitive display of three-se working information.
  • 9. Intelligent mobile monitoring cards are supported to monitor UPS data in real time through mobile apps.

PARAMETER XT33 10-40KVA

ModelXT33 10KVAXT33 10KSXT33 20KVAXT33 20KSXT33 30KSXT33 40KS
Rated Power 10kVA/9kW20kVA/18kW30kVA/27kW40kVA/36kW
InputVoltage Range207-475Vac 3P4W+G
Working Frequency Range40-70Hz (settable)
Input Power Factor≥0.95
OutputRated Voltage and Accuracy380Vac(1±1%) 3P4W+G
Output Frequency46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz ); 50Hz(Battery)
Rated Current15A30A45A61A
Output Power Factor0.9
Output Harmonic Wave≤3%
Crest Factor 3:1
Output Overload105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1min;125%±5%<Load≤150%±5%: Convert to bypass output and alarm after 30s;Load>150%±5%: Convert to bypass output and alarm after 300ms.
Conversion time between Mains Power and Battery0ms
Efficiency>92%>91%
BatteryRated Voltage192Vdc±192Vdc
Quantity1632
Charging Current1A5.5A1A7.5A5.5A
Dimension (LxWxH) mm560x260x717533x260x501710x260x717710x260x717
Weight 72kg26kg98kg57.5kg58.5kg62kg
Working Temperature0℃-40℃
Working Humidity20%-95%
Noise≤60dB
Premium Services