Join today and be a part of the fastest growing B2B Network Join Now

Fire Resistance Test Machine

  • Origin: China
  • Supply Type: oem service
  • Min Order: 0.99

Supplier Info.

  • Company Name TESTech Instrument Technologies Co., Ltd.
  • Membership:Free
  • Business Type: Manufacturer, Trading Company, Buying Office, Agent, Distributor/Wholesaler, Government ministry/Bureau/Commission, Association, Business Service (Transportation, finance, travel, Ads, etc), Other
  • Employees Total
  • Annual Revenue

Description:

Fire-resistant cable refers to the cable that can keep a safe running time in the case of flame combustion.

China's national standard GB12666.6 (equivalent to IEC331) divides the fire resistance test into A, B two classes, The flame temperature of A grade is 950 ~ 1000 ℃, and the continue flaming time is 90min, B grade flame temperature is 750 ~ 800 ℃, flaming time is 90 min. In addition,tthe test specimen shall bear the rated voltage during the test.

TESTECH Fire Resistance Tester is designed according to the requirements of GB/T19216.11-2003 (alternative GB12666.6) and IEC60331-11,and used to obtain the refractory characteristics of a fire resistant cable or optical cable under flame conditions.

Model:FTech-IEC60331

User’ s Experience:

1, This cabinet is made of stainless steel, anti-smoke and gas corrosion.

2, The control system is designed with a high degree of automation, automatic ignition, temperature and time digital display, convenient to observe and record, stable and reliable.

Standards

• IEC 60331 Part 11

• IEC 60331 Part 21

Main Features:

1, All fixtures are made of stainless steel;

2, The burner is a belt type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm;

3, Those burning holes are staggered into 3 rows, and the front width is 15mm, holes diameter is 1.32mm and these holes center distance is 3.2mm;

5, One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;

6, The cable sample is supported by two metal rings, and the middle length of the two rings is about 300mm;

7, An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.

8, The position of the burner torch from burning the bottom is not less than 200mm, and not less than 300mm from the tank wall.

Combustion System:

1, Independent standard electrical control platform;

2, With intelligent detection function, when a short circuit in the sample during the test, automatic alarm and turn off the fire source.

3, Fuse current in the experimental circuit is 2A;

4, The sample is applied to power of AV 100V ~ 1000V adjustable;

5, The time can be set free for the fire, the time recommended by standards is 90min.

Device parameters:

1, Voltage: AC 380V 3-se, 50 / 60Hz, 30A;

2, The input voltage 0 ~ 1000V; can be adjusted;

3, The breakdown current is 2A;

4, Maximum power: 5000VA;

5. Timer: 0 ~ 999min

6, The flame temperature of 0 ~ 1100 ℃ adjustable;

7, The test load current is 0.25A, can be adjusted;

Specification

1. Size: 1,600 (W) × 850 (D) × 1,650 (H) mm

2, Console size: 600 (W) × 750 (D) × 1,200 (H) mm

3, Power: AC 380V 3-se, 50 / 60Hz, 30A

4. Weight: 100kg

Premium Services
Tell us your Requirement
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok