The two poles can ignite separately or simultaneously. If they ignite simutaneously, they will ignite alternately every 1S. | ||
If the flame is out in ignition time, it can ignite again. | ||
It is with alarm function. | ||
The working zes with valve holding pan> | ||
Main technical parameter | ||
Test item | Standard | Note |
Rated operating voltage | 3V |
|
Operating voltage range | 2-3.3VDC |
|
Ignition frequency | 8-15Hz | 3V |
â¥4Hz | 2.1V | |
Ignition distance | â¥5mm |
|
Ignition current | â¤120mA |
|
Valve open current | â¥450mA |
|
Valve holding voltage | â¥2.8V |
|
Ignition time | 8±1s | 3V |
Igniiton No. | 1 time |
|
Valve keep open time after ignition | 0.2±0.1s |
|
Valve open time | 0.5±0.1s |
|
Flame detection sensibility | 1N4007+15M |
|
Ignition energy | â¥1mJ |
|
Ignition cycle | â¤400ms |
|
Output hi-voltage | â¥12KV | with 30pF loading |
Ignition pulse width | â¥12us |
|
Operating current | â¤150mA |
|
Operating ambient humdity | ï¼95% |
|
Operating ambient temperature | -10ï½70â |
|
Storage temperature | -20ï½75â |
|
Life cycle | ABS antiflaming>100,000 cycles |