CSA approval Constant Temperature Water Heater Control Board BW-HK002R

  • Origin: China
  • Supply Type: in stock
  • Processing Time: 20-25 days

Supplier Info.

  • Employees Total Over 1000
  • Annual Revenue Above US$100 Million

gas water heater control board Function description

1) It works with a display.

2) It works with a ventilator.

3) It works with a on-off valve, a proportional valve and a section valve.

4) It is with a buzzer.

5) It has AC ionization flame .

6) Status keeping function: If the nP menu was set as ON, after power on again, the system

will return to the last status before the power is cut off.

7) Flue pipe block-up protection.

8) Malfunction protection and warning function.

9) Compliance with Standard: BS EN298: 2012. ANSI Z21.20 -2014. CAN/CSA C22.2 No. 60730-2-5-2014.

More information you can click here

Main technical parameters

Working voltage range

90VAC ~ 120VAC

Rated voltage

120VAC 60Hz

Power frequency

50/60Hz±5%

Rated frequency

50Hz

Dielectric strength(V/1min)

1800V, 0.5mA, 3S

Working ambient temperature

-10℃~70℃

Ambient temperature

-20℃~70℃

Life cycle

≥50,000 times

Temperature setting range

35-65℃

High temperature protection

when the output water temperature ≥85℃ for 3S

Pre- cleaning time

2S

After cleaning time

20s

Start-up water flow

≤3L/min

Closing water flow

≤2.5L/min

Ignition time

8±1S

Cleaning time before 2nd ignition

3S

Max. allowable No. of ignition

2

Valve moving pulse

0.5±0.05S

24V Valve open voltage

≥24V

24V Valve holding voltage

≥8.5V

Output voltage of switch power supply

5VDC (with 300mA working current)

30±1.5VDC(with 510mA working current)

12±1VDC(with 110mA working current)

Ion sensibility of flame detection

≥5.1MΩ

Temperature detection precision

±2℃

Waiting time of reaching setted temperature

≤35S

Water temperature overshoot range

±3℃

Timing tolerance

±1 minutes

Post-purge time

20±2s

Time to achieve safe shut down

<1s

Trial for ignition period

7.5±1s