Join today and be a part of the fastest growing B2B Network Join Now

Carl Zeiss Cirrus 4000 Spectral Domain OCT HD Windows 7 OS w Quad Core Processor

  • Origin: United States
  • Supply Type: in stock
  • Processing Time: 7 days

Quick Details

White Black

Supplier Info.

  • Employees Total 501-1000
  • Annual Revenue US$50 Million - US$100 Million

The ZEISS Cirrus HD-OCT 4000 (Cirrus HD-OCT or Cirrus) enable examination of the posterior and anterior of the eye at an extremely fine spatial scale, without surgical biopsy or even any with the eye. The Cirrus HD-OCT builds on and refines the retinal imaging technology first introduced with the ZEISS Stratus OCT™. HD-OCT stands for "high-definition optical coherence tomogra."Employing the advanced imaging technology of spectral domain optical coherence tomogra, Cirrus HD-OCT acquires OCT data about 70 times faster (27,000 vs. 400 A-scans per second) and with better resolution (5 μm vs. ~10 μm axial resolution in tissue), compared to first-generation OCT technology. Cirrus acquires whole cubes of OCT image data, composed of hundreds of s, in about the same time as Stratus acquires a six-. You can view these data cubes in three planes, or through three dimensions, giving you access to an extensive amount of retinal image data in one scan.Intended UseThe Cirrus HD-OCT with Retinal Nerve Fiber Layer (RNFL), Macular, Optic Nerve Head, and Ganglion mative Databases is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures.Indications for UseThe Cirrus HD-OCT is a non- high resolution tomograc and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.Note: The Cirrus HD-OCT is not intended to be used as the sole diagnostic for disease.Essential PerformanceThe Essential Performance of the instrument is to provide accurate measurements of anterior and posterior ocular structure.Patient PopulationThe Cirrus HD-OCT may be used on all adults in need of diagnostic evaluation of the eye. This includes (but is not limited to) patients with the following disabilities or challenges:• Wheelchair user• Very low or not measurable visual acuity• Fixation problems• Postural problems• Deafness• Large body, but not those above 99th percentile based on anthropomorc dataThere is a general requirement that the patient be able to sit upright and be able to place their face in the chin and forehead rest of the instrument (with or without supplemental human or mechanical support).Cirrus HD-OCT is designed for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures.Specifications:HD-OCT ImagingMethodology: Spectral Domain OCTOptical Source: superluminescent diode (SLD), 840 nmOptical Power: < 725 μW at the corneaScan Speed: 27,000 A-scans per secondA-Scan depth: 2.0 mm (in tissue), 1024 pointsAxial resolution: 5 μm (in tissue)Transverse resolution: 15 μm (in tissue)Fundus ImagingMethodology: ning ohalmoscopeLive Fundus Image: During alignment and during OCT scanOptical Source: Superluminescent diode (SLD), 750 nmOptical Power: < 1.5 mW at the corneaField of View: 36 degrees W x 30 degrees HFrame rate: >20 HzTransverse resolution: 25 μm (in tissue)Iris ImagingMethodology: CCD CameraResolution: 1280 x 1024Live iris image: During alignmentElectrical, sical and EnvironementalWeight: 38kg (83 lbs)Dimensions: 65L x 44W x 53H (cm)Fixation: Internal, externalInternal fixation focus adjustment: -20D to +20D (diopters)Input devices: Keyboard, mouseElectrical rating (115V) Single se, 100/120V~ systems:50-60Hz, 5AFuse rating (115V) T 5A 250VElectrical rating (230V) Single se, 220/240V~ systems:50-60 Hz, 2.5AFuse rating (230V) Fuse rating: T 5A 250VConvenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 HzTemperature (transport and storage) -40º to +70º CRelative humidity (transport and storage) 10% to 100%, including condensationAtmosric pressure (transport and storage): 500 hPa to 1060 hPaTemperature (operation) +10º to +35º CRelative humidity (operation) 30% to 75%, excluding condensationAtmosric Pressure (operation) 700 hPa to 1060 hPaComputer• High performance multi-core processor• Internal storage: > 80,000 scans• CD-RW, DVD-ROM drive• Integrated 15" color flat panel display

Size:65L x 44W x 53H (cm)
Weight:38kg (83 lbs)
Amperage:10A
Frequency (Hz):50-60Hz
Power Supply Voltage:110/220 VAC

We ship to all locations and we are very ready to serve you, For purchase and inquiries, Message GoldenMed Hospitech via @

, or call us Tel: plus you can visit our website @

so they can best assist you., We also have both new and refurbished ones in exnt shape, we're certain that it works for you

Premium Services
Tell us what you need
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok