1. General requirements 1-1. The specification is applied to tact switch used in the circuit of low current. 1-2. Operating temperature : -40â to +85â 1-3. Storage temperature : -40â to +85â 1-4. Test conditions : Temperature - 5â to 35â, : Relative humidity - 45%RH to 85%RH : Atmosric pressure - 86kPa to 106kPa (860mbar ~ 1060mbar) If there is an objection to a judgment, the following conditions shall be appled âTemperature : 20±2â, Relative humidity:65±5%RH, Atmosric pressure: 86kPa to 106kPa (860mbar ~ 1060mbar) 2. Appearance & Dimensions : Refer to the drawing 3. Electrical arrangement : single pole, single throw (The two terminlas are either connected together or disconnected from each other) 4. Arrangement of operation : Tactile feed-back 5. Maximum rating : D.C 12V, 50mA
6-1. resistance Applying static load twice the operating force to the center of the Stem, measurements shall be made with a 1 kHz small-current resistance meter 100m⦠Max. 6-2. Insulation resistanceMeasurements shall be made following application of D.C 100V potential between terminals and between individual terminals and frame for 1 minute. 100M⦠Min. 6-3. Dielectric withstanding voltage A.C 250V(50Hz to 60Hz)is applied between terminals and between terminals and frame for 1 minute. There shall be no breakdown 6-4. Bounce Lightly pushing the center of the Stem at a rate of 3 operations/sec. Bounce shall be tested when ON and OFF 10 ms Max.