⢠CDS2000 : CO2 Detector, Space type, 0~2,000ppm, 0 ~ 10Vdc / 0~20mAdc output⢠CDS2000-L : CO2 Detector, Space type, 0~2,000ppm, LCD, 0 ~ 10Vdc / 0~20mAdc output, Relay output⢠CDS2000_M : CO2 Detector, Space type, 0~2,000ppm, LCD, 0 ~ 10Vdc / 0~20mAdc output, Modbus output, Relay output
Features⢠High sensitivity and good resolution⢠Based on non-dispersive infrared(NDIR) technology⢠Two types of analog DCA) output (Selectable)⢠Eliminates the need for manual calibration in most applications with ABC logic software⢠On/Off relay output for CO2 limit monitoring⢠Long term stability and lifetime (>10years)⢠Optional Modbus communication⢠Optional LCD display⢠Low Power consumption⢠Easy installation⢠CE Certification
Advantages⢠Manufactured in own factory⢠Honeywell gas detector ODM supplier in Asia
Wiring Diagram
Specifications
Gas detected | Carbon dioxide (CO2) |
Sensing method | NDIR (Non-dispersive infrared) |
Detect range | 0 ~ 2,000ppm |
Accuracy | ±30ppm ±5% of measured value |
Power consumption | 2W max. |
Power supply | 24Vac, 24Vdc±20%, 50/60Hz |
Maintenance interval | Not required |
Output ~10Vdc(default) or 0~20mA (selectable by jumper setting)Modbus RTU |
Relay(Alarm) output | SPST relay, normally open, 1A/120Vac, 1A/24Vdc rating,Activated at greater than 1,000ppm, deactivated at less than 900ppm |
Coverage area | Approximately 100m2 |
Response time | Within 120 sec. (90% step) |
Wiring | 3 or 4 le |
Optional Modbus | Hardware : 2->Software : Native Modbus MS/TP protocol (RTU or ASCII)Baud Rate : Locally set t, 2400, 4800, 9600, 19200, 38400, 57600, 76800 or 115200Slave Address Range : Locally set to 0-64 (factory default is 1), (32 devices max on one daisy chain) |
Operating temperature | 0 ~ 50â |
Operating humidity | 0 ~ 95%RH (non condensing) |
Storage temperature | -20 ~ 60â |
Storage humidity | 0 ~ 95%RH (non condensing) |
Sensor life expectancy | >10 years |
Housing material | Plastic(ABS), Flame retarded acc. to UL94-V1 |
Caution on Use
⢠Do not use this device for outdoor use. This product is provided only for indoor use.⢠Do not use this device for where a building is continuously occupied 24 hours per day, or where there could be significant sources of non-occupant related CO2 such as greenhouses, breweries and other industrial and food processing applications.⢠Do not use this device for medical or safety purpose.⢠Do not leave or use the device for longtime in a highly-damped place in which humidity is near 95%RH.⢠The standard test condition in which the product was tested is 25â±3â, 50â±30%RH. slightly by environment condition.⢠This device must abide by the operating temperature/humidity and the storage temperature/humidity.⢠Use the product when it is completely fixed and do not use it while it is in motion.⢠We do not guarantee the performance of the device in the case of user installation, disassembling and inspection. When installing and inspection is necessary, please our technicians.⢠NDIR sensor can be influenced by air pressure. It can be used without correction within 300M above the sea level. However, add the output value by +1.0% per 100M height above 300M.Ex) If the output 600ppm at the height of 500M, correct the output value to 630ppm by adding 30(600*0.01*5)ppm.⢠Be careful when install and use the product as vibration, shock, and falling can cause a serious damage on the sensor.