Join today and be a part of the fastest growing B2B Network Join Now

AS-Interface EMERGENCY STOP button VAA-2E-F85A-S-V1

  • Origin: Germany

Supplier Info.

  • Company Name FAMAGA GROUP
  • Membership:Free
  • Business Type: Distributor/Wholesaler
  • Employees Total 11-50
  • Annual Revenue
  • 2-channel, compelled connected
  • Outwit-proof according to ISO 13850/EN 418
  • TÃœV-approval for system components is available
  • Biased actuator for self-monitoring
  • EMERGENCY STOP unlocking by turning or pulling
  • M12 plug connection
This AS-Interface emergency shutoff button is a two-channel, positively driven allowing the operation of personnel protection systems when used according to specification along with an AS-Interface safety monitor. It occupies one complete address in the AS-Interface strand. When the safety monitor is properly configured, up to EN 954-1 Category 4 and IEC 61508 SIL 3 can be achieved. For mounting, the housing of this AS-Interface emergency shutoff button can be screwed directly onto the machine. Product Description
AS-Interface EMERGENCY STOP button
General specifications Functional safety related parameters Electrical specifications Input Directive conformity Standard conformity Programming instructions Ambient conditions Mechanical specifications
Slave typeSafety-Slave
AS-Interface specificationV2.1
Required master specification&ge, V2.0
UL File /td>E198304
MTTFd200 a
B10d1 E+5
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current&le, 25 mA
Protection classIII
Insulation resistancemin. 100 M&Omega,
Type2 NC Safety function by positive opening in accordance with IEC/EN 60947-5-1 Reset by pulling
Supplyfrom AS-Interface
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Electromagnetic compatibilityEN 62026-2:2013
Degree of protectionEN 60529:2000
Electrical safetyEN 60947-5-5:1997+A1:2005
AS-InterfaceEN 62026-2:2013
Functional safetyEN 62061:2005 EN 61508 Parts 1-7:2010 NFPA 79:2007 EN 60204-1:2006
ProfileS-0.B.E
IO code0
ID codeB
ID1 codeF
ID2 codeE
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 -
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Ambient temperature-25 ... 55 °C (-13 ... 131 °F) (no freezing)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity40 ... 85 % , noncondensing
Operating forcePush: 32 N Pull: 21 N Turn: 0.27 Nm Minimum for positive opening operation: 60 Nm
Operating distancefor positive opening operation: min. 4 mm maximal: 4.5 mm
Degree of protectionIP65 Module: IP20
ConnectionM12 round connector
Material
HousingPC
Mass195 g
Life span> 250,000 switching operations