Moq | Piece |
Model | ATO-HSI-3kW48-230 | |
Rated Power | 3000W | |
PV INPUT (DC) | Maximum DC Power | 4500W |
Nominal DC Voltage | DC 360V | |
Maximum DC Voltage | DC 500V | |
Start-up Voltage / Initial Feeding Voltage | 116V/150V | |
MPP Voltage Range | DC 250V-DC 450V | |
Maximum Input Current | 18A | |
Isc PV (absolute maximum) | 18A | |
Max. inverter back feed current to the array | 0A | |
GRID OUTPUT (AC) | Nominal Output Voltage | AC 208/220/230/240V |
Output Voltage Range | AC 184V-265V | |
Output Frequency Range | 47.5-51.5Hz~59.3-60.5Hz | |
Nominal Output Current | 13A | |
Inrush Current/Duration | 17A | |
Maximum Output Fault Current/Duration | 51A | |
Maximum output Overcurrent Protection | 51A | |
Power Factor Range | 0.9 lead - 0.9 lag | |
AC INPUT | AC Start-up Voltage | AC 120V-140V |
Auto Restart Voltage | AC 180V | |
Acceptable Input Voltage Range | AC 170V-280V | |
Nominal Frequency | 50Hz / 60Hz | |
AC Input Power | 5100VA / 5100W | |
Maximum AC Input Current | 30A | |
Inrush Input Current | 30A | |
BATTERY MODE OUTPUT (AC) | Nominal Output Voltage | AC 208/220/230/240V |
Output Frequency Range | 50 Hz / 60 Hz (auto sensing) | |
Output Waveform | Pure sine wave | |
Output Power | 3000VA/3000W | |
Output Current | 14.4A/13.6A/13A/12.5A | |
Efficiency (DC to AC) | 92% | |
BATTERY & CHARGER (Lead-acid/Li-ion) | Nominal DC Voltage | DC 48V |
Maximum Battery Discharging Current | 92A | |
Maximum Charging Current | 25A | |
GENERAL SICAL | Dimension, D*W*H (mm) | 480*438*117 |
Net Weight (kgs) | 15.57 | |
INTERACE | Communication Port | RS-232/USB |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available | |
ENVIRONMENT | Protective Class | I |
Ingress Protection Rating | IP20 | |
Humidity | 0 ~ 90% RH (No condensing) | |
Operating Temperature | 0 to 40°C | |
Altitude | 0-1000m* |