PD1056-2N Single-Phase Electronic DC Multifunction Energy Meter

  • Origin: China
  • Location: changsha

Supplier Info.

  • Location changsha
  • Employees Total Over 1000
  • Annual Revenue
Characteristic

PD1056-2N single-se electronic DC multifunction energy meter is an electric meter integrating measurement, metering, LCD and communication. It can measure power grid voltage, current, power and electric energy. Its communication interface supports MODBUS-RTU communication protocol. 2-way on-off input and 2-way on-off output are optional for the meter, which can realize local or remote on-off g and control output functions (i.e. “remote € and “remote control” functions), or 1-way transmitting output which can be controlled flexibly is optional. This single-se electronic DC multifunction energy meter conforms to the following standards: ZB Y318—85  Technical Conditions of Electronic DC Energy Meter JJG842—1993 Verification Conditions of DC Energy Meter MODBUS-RTU Communication Protocol GB/T13850-1998 Transmission Standard Â

Function
  • Real-time measurement of electric power parameters, simple metering of energy;

  • Transformation ratio display operated via button on the panel, arbitrary setting, flexible use;

  • Optional for transmitting output of measured value, analog quantity output: 4-20Ma, 0-24Ma, 0-5V, 0-10V;

  • Optional for FS485 communication interface, standard MODBUS protocol;

  • High precision and high performance cost ratio for digital zero setting and rectification;

  • Wide range of application and strong combination function.

Parameters

Item

Performance parameter

Specification

Single se

Measurement Â

DC voltage

Input range

0~1.2Un

Impedance

>2MΩ

DC current

Current specification

Shunt rated voltage input:50mV 75mV 100mV

Power consumption

<0.05VA(one-way rated current)

Power

Accuracy 0.5%

Metering

Electric energy

Electric energy (accuracy class: Class 1)

Digital pan>

Electric quantity pulse output

1-way optocoupler output

Optional function (only one function can be selected)

Switching value function

2-way mechanical relay output (250V(AC)/3A and 30V(DC)/3A)

2-way dry input

Transmitting pan>

Transmitting (1 way) 4mA~20mA, 0mA~20mA, 0mA~24mA, 0V~5V and 0V~10V which can be selected flexibly

Accuracy class is superior to Class 0.5

Communication

Interface and communication protocol

RS485 interface: Modbus RTU protocol

Communication address range

Modbus RTU: 0~ 247;Â

Baud rate

1200bps~9600bps

Environment

Operating temperature

-25℃~+60℃

Operating temperature limit

-35℃~+70℃

Relative humility

≤95% (without condensation)

Working power supply

DC-AC power supply(range: 40V~265V) Power consumption: ≤1W, 2VA

Dimensions

Overall dimensions(mm): 96×48×113 Hole size (mm): 92×45

Weight

450g

Pictures

Cathode Side Wiring Diagram Anode Side Wiring Diagram Since isolation measures are not adopted inside the meter for voltage current ase note that the voltage difference between voltage terminal and current terminal can’t be greater than 5V upon connection. Â

Premium Services
Need Free Quotes
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok