Isolated Positive and Negative 0-5V to RS232/RS485 A-D Converter ISO 4021 Series

  • Origin: China
  • Location: 2nd Floor, Building#6, Dongyi Industrial Park, Zhonghuan Road, Minzhi St. Longhua New District, Shenzhen
  • Supply Type: oem service

Supplier Info.

  • Location 2nd Floor, Building#6, Dongyi Industrial Park, Zhonghuan Road, Minzhi St. Longhua New District, Shenzhen
  • Employees Total 51-100
  • Annual Revenue

Analog data acquisition isolated AD conversion amplifier module. Shunyuan technology patented products

Product Description

ISO4021 Series Isolated 0-±100mV,0-±10V,4-20mA,0-±20mA to RS232/RS485 A-D Converter

Model selection:

ISO 4021 U(A)â–¡ - â–¡

U/A: Input voltage or current ommunication interface

U1:0-5V A1:0-1mA 232/485: Output is RS-232 or RS-485 interface

U2:0-10V A2:0-10mA

U3:0-75mV A3:0-20mA

U4:0-2.5V A4:4-20mA

U5:0-±5V A5:0-±1mA

U6:0-±10V A6:0-±10mA

U7:0-±100mV A7:0-±20mA

U8:Customized A8:Customized

Remark:When the communication interface is RS232, it should connect with RXD and TXD port; when the communication interface is RS485, it should connect with DATA+ and DATA- Port. RS232 and RS485 can’t work at the same time.

E.g.

1: ISO 4021 A4-232/485 Means 4-20ma tput is RS232 or RS485

2: ISO 4021 U1-232/485 Means 0-5V tput is RS232 or RS485

3: ISO 4021 U5-232/485 Means 0-±5V tput is RS485 or RS232

ISO 4021 A-D Converter General Parameters:

(typical @ +25℃,Vs is 24VDC)

Input: Voltage / Current

Accuracy: 0.05%

Input imbalance: ±0.1 uA/℃

Temperature Drift: ±15 ppm/℃ (±30 ppm/℃, max)

Input Resistance: 50Ω (4-20mA/0-20mA/0-±20mA current input)

100Ω (0-10mA/0-±10mA current input)

1KΩ (0-1mA/0-±1mA current input)

>1MΩ(voltage input)

Band width: -3 dB 10 Hz

Switching rate: 10 Sps

Common mode restraint(CMR): 120 dB(1kΩ Source Imbalance @ 50/60 Hz)

Normal mode restraint(NMR): 60 dB (1kΩ Source Imbalance @ 50/60 Hz)

Input Port protection: over-voltage/over current protection

Communications: protocol RS-485 or RS-232 ASCII protocol and MODBUS RTU communication protocol

Baud rate(300、600、1200、2400、4800、9600、19200、38400bps)software configuration

address(00H~FFH)software configuration

Response Time:100 ms max

Operation Power Supply: +8 ~ 50 VDC wide power supply range, internal anti-reverse & over-voltage protection

watt consumption: < 1W

Operation Temperature: - 45 ~ +80℃

Operation Humidity: 10 ~ 90% (non-condensing)

Storage Temperature: - 45 ~ +80℃

Storage Humidity: 10 ~ 95% (non-condensing)

Isolation withstand voltage: between input and output: 3KVDC,1 minute,stray current 1mA

Output and power are common-ground.

Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)

Dimensions: 83 mm x 37 mm x 51mm