 Current temperature on-tor and fault is the ring net switch cabinet, cable branch box, box installed in the power distribution network system becomes,for a real-time ontoring device indicates the corresponding section of the cable short circuit and ground fault current, temperature and time. When the n trouble, the staff can quickly determine the fault section by the warning indication of the indicator, and find out the fault point. At the same time, real-time alarm information can be sent to the monitoring center server, a regional fault location and location for monitoring the computer screen, the guide ol officers to quickly determine the fault section and find the point of failure. In order to solve the problem of fault finding, it provides the best way to improve the work efficiency, shorten the outage time, quickly restore the power supply, and improve the reliability and economic efficiency of power supply, which is of great significance.Specification

ITEMDETAILS
Short circuit fault current alarm1A~10000A(Error±3% Set according to the customers' demand when leave factory)
Grounding fault current alarm4A~120A  (Error±3% Set according to the customers' demand when leave factory)
Cable temperature fault alarm-40℃~120℃(Error±3% Set according to the customers' demand when leave factory)
Cable current / temperature test range in real time1A~10000A / -40℃~120℃
Working power supplyER14505 Industrial lithium battery3.6vExternal power supply DC5~18V, current less than 5mA
The machine power consumption standby current≤5 u A
Protection gradeThe host; IP 40 Electronic;IP 65’
Short circuit current sensor maximum current20 k A 4 s
The host work environment-40℃~75℃
Communication methods:

RS-485 communication;Support 101.103.MODBUS etc. Various kinds of specification agreement

SNV300 Ontor for cable temperature and faults