KRD11 series pneumatic vertical shock test system is featured with advanced design, high degree of automation and reliability, simple operation and convenient maintenance. The system meets the requirements of both shock and bump test, can perform conventional half-sine wave, post-peak sawtooth wave, trapezoid wave and other waveform shock tests.
Pneumatic drive, simple structure and high reliability, without hydraulic leak risk.
Maximum shock rate up to 120 times / min.
Impact testing for small pulse lower to 0.3ms
Shock testing machine with high acceleration is up to 3000g
It can easily realize large shock pulse width and small overload test.
With a fast shock rate comparing to motor or hydraulic driven bump table, it has higher reliability and better bump waveform.
The speed and rate of shock can be easily controlled by adjusting the gas pressure.
IPS-2000 shock control and measurement system can perform manual shock, continuous shock (bump test), single shock, and interval shock.
Built-in brake mechanism ensures the safety of operation in any situation.
Technical Specifications
Model Parameters | KRD 11ï¼5 | KRD 11ï¼15 | KRD 11ï¼25 | KRD 11ï¼50 | KRD 11ï¼100 | KRD 11ï¼200 | KRD 11ï¼400 | KRD 11ï¼600 | KRD 11ï¼800 | KRD 11ï¼1000 | KRD 11ï¼2000 | |
Rated Load (kg) | 5 | 15 | 25 | 50 | 100 | 200 | 400 | 600 | 800 | 1000 | 2000 | |
Table Size (mm) | 150Ã150 | 200Ã200 | 300Ã300 | 500Ã500 | 600Ã600 | 800Ã600 | 800Ã800 | 1000Ã800 | 1000Ã1000 | 1200Ã1200 | 1500Ã1200 | |
Peak Acc. (g) | Half-Sine | 5-2500 | 5-2000 | 5-1500 | 10-750 | 10-600 | 10-450 | 10-400 | 10-300 | 10ï½300 | 10ï½250 | 10ï½150 |
Post-Peak Sawtooth | 10-200 | 10-100 | 10-50 | |||||||||
Trapezoid | \ | 15-200 | 15-100 | 15-60 | 15-50 | |||||||
Pulse Duration (ms) | Half-Sine | 0.4ï½40 | 0.5ï½40 | 0.6ï½60 | 1.5ï½60 | 2ï½60 | 2.5ï½60 | 3ï½60 | 3.5ï½60 | 4ï½60 | 4.5ï½60 | 6ï½60 |
Post-Peak Sawtooth | 3ï½18 | 6ï½18 | ||||||||||
Trapezoid | \ | 3ï½18 | 6ï½18 | |||||||||
Bump Waveform (Optional) | Half sine waveveform | |||||||||||
Bump Peak Acceleration ï¼gï¼ | 5~150 | 5~120 | 5~100 | 5~80 | 5~60 | 5~40 | \ | |||||
Bump Pulse Duration (ms) | 2~30 | 3~30 | 4 ~ 30 | 5 ~ 30 | \ | |||||||
Bump Rate (Times/Min) | 10~120 | 10~100 | 10~80 | 10~60 | 10~40 | 10~30 | \ | |||||
Overall Dimension (mm) | 1000Ã1000 Ã2100 | 1000Ã1000 Ã2160 | 1510Ã1300 Ã2400 | 1690Ã1240 Ã2350 | 1710*1160 *2350 | 1910*1500 *2700 | 1910Ã1500 Ã2500 | 1900Ã1500 Ã2450 | 2000Ã1500 Ã2450 | 1900Ã1800 Ã2550 | 2200Ã1800 Ã2550 | |
Weight (kg) | 1300 | 2300 | 3000 | 3070 | 3900 | 4500 | 5000 | 5200 | 5600 | 6200 | 7300 | |
Working Environment | Temperature range 0 ~ 40â, Humidityâ¤80% (non-condensing) | |||||||||||
Power | 1-se AC220V±10% 50Hz | |||||||||||
Air source | â¤0.8MPa | |||||||||||
Installation Condition | Foundation-free, the cement floor shall be leveled and the working distance of 800 ~ 1000mm shall be reserved around the equipment | |||||||||||
Standards | MIL-STD-810F IEC68-2-27 MIL-STD-202 MIL-STD-750 MIL-STD-883 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580 |