FUJI FKC Differential pressure transmitter ( FUJI FKC Flow Transmitterï¼FUJI FDC Differential pressure transmitter ( FUJI FDC Flow Transmitterï¼FUJI FKC Flow transmitter ( FUJI FKC ï¼FUJI FDC Flow transmitter ( FUJI FDCï¼1.Product Introduce
The Fuji FCX -AIII differential pressure (flow) transmitter accurately measures differential pressure and converts it into an output DC.
Fuji transmitter utilizes a unique micromachined capacitance silicon sensor with advanced floating capsule structure and newer micro-processing technology, the transmitter has high accuracy, good stability, safety and reliability, and easy to use.
It's small volume, light weight, good environment adaptability, and applicable to all fields.
If using the hand held communicator(sold separately), it can be set and display via remote operation, without affecting the DC 4~20mA output itter.Fuji FCX-AIII series transmitters with safety funtion have obtained the certificate of SIL certification by TÃV.2ï¼Fuji FKC Transmitter Features
a. High accuracy
Differential pressure (flow) transmitter can be carried out with high accuracy measurement in the range of 0.1ï½20000kPa.
Standard accuracy: ± 0.065%
High accuracy(optional)ï¼Â± 0.05%
There's no need to libration when carrying out zero elevation or suppression.
b. Exnt environmental adaptaboilityThe advanced floating protects sensor from temperature,static pressure and overpressure effect, and controls the total measurement error of the filed to the minimun.
c. Exnt operability and easy to use
It has an exnt operability and easy to use in any application.
· All range meet the requirements of explosion-proof.
· 5-digit digital indiactor
· Stainless steel AMP case
·Built-in RFI filter and lightning arrester
· Various anti-corrosive materials
· Built-in local configurator with 3 push buttons
d.The transmitter can communicate using FUJI, HART, communication protocol, and also can use FOUNDATION FIELDBUS or PROFIBUS protocol after changing the electronic circuit.
3:Product SpecificationMeasured fluid: Liquid,Gas,or vapourRange, operating pressure, and overrange limit:
Output DC4~20mA+HART protocol
(2)FDC: FOUNDA TION Fieldbus protocol or PROFIBUS-PA
Power Supply:
General | DC10.5 ï½ 45V |
Intrinsic safety | DC10.5 ï½ 26V |
With arrestor | DC10.5 ï½ 32V |
5ï¼Process temperature, Lower range limit: Refer to Below TableFill fluid | 13th digitCode | Process (Note)Temperature | Lower range limit |
Silicone oil | Y, G, N | -40ï½+120°C | 2.7kPa abs |
Fluorinated oil | W, A, D | -20ï½+80°C | Atmosric pressure |
Silicone oil | R | -15ï½+120°C | 2.7kPa abs |
7ï¼Approved Explosion -proof |