PRODUCT OVERVIEW
1MW generator load bank has the functions of static, fluctuation, sudden loading and unloading test of diesel generator set, real-time data acquisition, display, analysis, report and so on; Data storage adopts local storage and centralized display in the center to ensure data integrity and safety; Provide visual display and automatic analysis of various data charts, and provide analysis results; The functions of generator setting test, fluctuation test and transient test (sudden load addition and sudden load unloading) can test the maximum and minimum voltage, maximum and minimum current, maximum and minimum frequency and recovery time in case of sudden load change; 1MW load bank can not only measure all steady-state parameters, but also measure sudden addition, sudden discharge, voltage, current, frequency curve, voltage and current harmonic curve and harmonic content; It can complete the measurement of all electrical parameters of the generator. Automatically generate various charts and manually make charts, curves and test reports. Standardized operation and strong authority. Rich data content, strong report applicability, and can sign and change the format according to the needs of users; It has the function of harmonic analysis, and can analyze the 2 ~ 50th harmonic content and total harmonic content of voltage and current at the same time; Electric energy accumulation function; The system can meet the test of national standard, ship standard, military standard and telecommunication standard, and the test accuracy can meet the standard requirements.
APPLICATION SCENARIO
PARTIAL PARAMETERS
Note: all parameters are for reference only and can be customized | |
Product name | 1MW generator load bank |
Specifications | R1000kW/400V/50Hz |
Steps | 1kW,2*2kW,5kW,2*10kW,20kW,50kW,9*100kW |
Formation | One load bank(Including dry resistance load, electrical control components, measurement and control system) |
Load step | According to customer needs |
Load connection | Copper bar |
Resistor | Each resistance on impedance DC1000V/100MΩ above Withstand voltage ac 2000v for 5min Resistance error of each resistance tube:±3% |
Load control | Local manual control, local automatic control or remote automatic control can be selected |
Loading accuracy | Less than or equal to 3% |
Three se balance | Unbalance degree less than or equal to 3% |
Minimum step | 1kW |
Working mode | Continuous work |
Load protection | Short circuit, overcurrent, high temperature, fan fault protection |
External power | TN-C,380V/50Hz |
Cooling mode | Forced air cooling, side air outlet or top air outlet |
Insulation class | F |
Measurement accuracy | The display accuracy is 0.5,the sampling accuracy is 0.2 |
Electrical parameter display | Three se voltage, three-se current, frequency, power, etc |
Load expansion | Parallel expansion of multiple load containers |
Standard | Meet international standard, ship standard, military standard and telecommunication standard |
Transport | The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation |
Color | Customized |
Ambient temperature | -20â to 50â |
Humidity | Up to 100% |
Altitude | Up to 2500m |
Atmosric pressure | 86 to 106kPa |