500kW resistive load bank

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 20

Supplier Info.

  • Employees Total 11-50
  • Annual Revenue US$2.5 Million - US$5 Million

PRODUCT OVERVIEW

Rata-R500kW/400V/50Hz generator load bank is a full resistive load bank developed and produced by our company. The power factor is 1.0 and meets the indoor or outdoor voltage test of 400V/690V. The load bank can test the performance of power equipment such as generator set, UPS standby power supply, emergency power supply vehicle and transformer. Rata's 500kW load bank can customize the function or appearance completely according to the needs of customers, with high customer satisfactio.

PRODUCT PICTURE

APPLICATION SCENARIO

PARTIAL PARAMETERS

Note: all parameters are for reference only and can be customized

Product name

500kW load bank

Specifications

R500kW/400V/690V/50Hz

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load step

According to customer needs

Load connection

Copper bar

Resistor

Each resistance on impedance DC1000V/100MΩ above

Withstand voltage ac 2000v for 5min

Resistance error of each resistance tube:±3%

Load control

Local manual control, local automatic control or remote automatic control can be selected

Loading accuracy

Less than or equal to 3%

Three se balance

Unbalance degree less than or equal to 3%

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

TN-C,380V/50Hz

Cooling mode

Forced air cooling, side air outlet or top air outlet

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three se voltage, three-se current, frequency, power, etc

Load expansion

Parallel expansion of multiple load containers

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation

Color

Customized

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmosric pressure

86 to 106kPa

MORE SPECIFICATIONS

Note: all parameters are for reference only and can be customized

Power(kW)

Voltage(kV)

Frequency(Hz)

Size(mm,L*W*H)

Weight(Kg)

Low voltage

100

0.4

50