Join today and be a part of the fastest growing B2B Network Join Now

ZJA Two Stage Vacuum Transformer Oil Filtration Machine/oil purifer

  • Origin: China
  • Supply Type: oem service
  • Processing Time: 30days
  • Min Order: 1

Supplier Info.

  • Employees Total
  • Annual Revenue

ZJA Two Stage Vacuum Transformer Oil Filtration Machine/oil purifer

Application

Regular purification of electrical insulating fluids/transformer oil is necessary to ensure longevity of your transformer. Moisture, Solids and Gaseous contamination can seriously affect the function of electrical insulating fluids as a coolant and insulator. LUSHUN ’s solutions offer a process of oil treatment utilizing the latest technology to suit your needs.

Duty & Performance

Lushun offers performance in a single pass through the purifier at full flow rate including:

Dielectric Strength:

Improvement in dielectric strength up to 70kv with new oil

Water Removal:

From 50ppm down to less than 5 ppm in a single pass and down to 3ppm after two passes as measured by the GB/T7600 for new oil

(subject to operating and environmental conditions)

Particulate removal:

98% of particles over 0.5 micrometer, or over 1 or 5 micrometer as your preference.

Gas Removal:

From fully saturated with air (10 to 12% by volume) down to less than 0.1% by volume as measured by the GB/T423

Item

Index

Unit

LS-ZJA-30

LS-ZJA-50

LS-ZJA-100

LS-ZJA-150

LS-ZJA-200

LS-ZJA-300

LS-ZJA-500

Technical Parameter of The Equipment

Flow Rate

L/H

1800

3000

6000

9000

12000

18000

30000

Working Vacuum Pressure

MPa

-0.08~-0.0999

Working Pressure

MPa

≤0.5

Constant Temperature Range

℃

20-80

Power Supply

V

380V/50Hz(can be customized)

Working Noise

dB(A)

≤70

Total Power

KW

30+5

40+5

60+6

90+10

120+10

135+15

180+35

Inlet/Outlet Diameter

mm

25

32

40

50

50

65

80

Net Weight

Kg

650

800

1000

1300

1800

2100

3500

Overall Dimension(L×W×H)

cm

120×132×165

130×140×180

154×185×200

198×167×215

198×167×215

204×250×235

350×260×250

Oil Index After Treatment

Breakdown Voltage

KV

≥70 (GB/T507) Nodulizing grade

Water Content

ppm

≤3(GB/T7600)

Gas Content

%

≤0.1(GB/T423)

Technical Parameter List