CEL-PF300-T10 xenon lamp light source system is widely used in tolysis of water, tolysis of aquatic hydrogen oxygen production, CO2 reduction, tothermal catalysis, VOCs degradation, tothermal synergy, tochemical catalysis, toinduced synthesis, todegradation of pollutants, water pollution treatment, biological light, optical detection, various types of simulated daylight, visible light, ultraviolet light, monochromatic light acceleration experiments and other fields.

CEL-PF300-T10 xenon lamp light source system adopts seven-inch touch color screen; intelligent control system; adopts fiber optic light feedback function to ensure the stable output of light source; can be used with the whole series of reactors and systems of CEL-Jinyuan; modular design, quick connection of accessories; adopts low pressure controllable speed fan to achieve constant heat dissipation and stable light output; realizes the safe work of the lamp box with low pressure; can be simple and fast by itself Safe lamp replacement.

CEL-PF300-T10 xenon lamp light source intelligent system to achieve automatic power on, off, optical power density display, calibration and automatic adjustment, custom switch times and frequency, to achieve digital monitoring, program mode can be based on the requirements of different stages of the experimental time automatically adjust the light intensity at the right time (can fully simulate the changes in daylight throughout the day). Through the expansion module can be used remotely with software or applet to achieve real-time ontoring of the light source.

Main parameters

CEL-PF300-T10

CEL-PF300UV-T10

Light stability

Fiber optic optical feedback achieves stable output of optical power density of xenon lamp light source; using fiber optic to channel the calibrated optical output into Hamamatsu sensor, which can discard the temperature drift of Hamamatsu sensor and achieve stable long-term and stable optical output.

Intelligent control system

The working time and working light intensity of the light source can be adjusted automatically according to the demand; the temperature monitoring of the bulb, power supply, sensor and many other places to ensure the stable operation of the light source.

Working mode

Regular use mode (without opening fiber optic optical feedback); fiber optic optical feedback mode; program intelligent mode; automatic mode, etc.

Optical power density display

Test point with optical power meter calibration (factory calibration display, working distance 15cm), to achieve real-time display of the working optical power density value; K-factor correction function, can be based on the actual measured value of real-time correction of light intensity output.

Luminous spectrum range SpectralOutput(nm)

(AULTT-P4000 measurement)

300nm~2500nm (without ozone)

200nm~2500nm (with ozone)

Working spot diameter

(optional continuous adjustment accessories)

60mm or more

60mm or more

UV Output, <390nm (Watts)

2.6W

6.6W

IR Output, >770nm (Watts)

28.8W

26.8W

Visible Output, 390-770nm (Lumens)

5000Lu、18.6W、5600K

4500Lu、16.6W、5050K

Input Power(Watts)

300W (Lighting voltage 30KV, working voltage 14V)

Working currentCurrent (Amps DC)

21A (10A~22A, 18A recommended)

Total luminous output power

50W (can replace the bulb quickly and safely by itself)

Lamp life Life (Hours)

>1000H Limit 6000H (dusty and humid environment will seriously affect the life)

Light output index

Light stability: <±1%

Temperature control system

Light source system using multi-point temperature monitoring to ensure stable output of light source.Fan speed delay automatically adjusts according to the system temperature to stabilize the light intensity output.

Optional accessories

CEL-LMP400 automatic lifting table; CEL-LB70 tochemistry experiment box

CEL-NP2000-2A Intense light power meter

Optional quartz coated filter

Conventional filters: UVIRCut400 (through 400-780nm), UVIRCut420 (through 420-780nm), Cut800 (through 800nm or more), AM1.5G (300-1100nm), AREF (full spectrum reflection, 200-2500nm), VisREF (standard with visible reflector. 350nm-780nm), UVREF (ultraviolet reflective sheet, 200-400nm).

Bandpass filters: QD254, QD275, QD280, QD295, QD300-800, QD313, QD320, QD325, QD330, QD334, QD350, QD355, QD360, QD365, QD370, QD375, QD380, QD400, QD405, QD420, QD435 QD420, QD435, QD450, QD475, QD500, QD520, QD550, QD578, QD600, QD630, QD650, QD670.QD700, QD730, QD765, QD850, QD940

Premium Services
Need Buyers
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok