Test Parameters | Ambient Temperature, Dew Point Temperature, Wet Bulb Temperature, Relative Humidity, Absolute Humidity, PPM, Thermocouple Surface Temperature |
Resolution | 0.01 |
Power | 4×1.5V AAA(UM-4) Battery |
Thermocouple Surface Temperature | -50~200 Celsius degree (-58~392 Fahrenheit degree) (-150-1372℃ can be customized) |
It is a high accuracy of professional dew point meter. It is able to measure Ambient Temperature, Dew Point Temperature, Wet Bulb Temperature, Relative Humidity, Absolute Humidity, PPM and Thermocouple Surface Temperature. It can quickly respond to temperature and humidity measurements in the industrial range. It is also capable of measuring temperature and humidity in a variety of complex environments. Widely used in laboratories, precision manufacturing, modern agriculture, meteorological measurement, chemical and rmaceutical fields.
⢠Large LCD with display. It can display three values at the same time.
⢠Ambient Temperature measurement.
⢠Dew Point Temperature measurement.
⢠Wet Bulb Temperature measurement.
⢠Relative Humidity measurement.
⢠Absolute Humidity measurement.
⢠PPM measurement.
⢠Thermocouple Surface Temperature measurement.
⢠Temperature unit (Fahrenheit degree/Celsius degree).
⢠0.01 resolution.
⢠High accuracy.
⢠With maximum and minimum values function.
⢠With the displayed values hold function.
⢠With battery indication function.
⢠With automatic power off function.
Display | Backlit LCD | |
Test Parameters | Ambient Temperature, Dew Point Temperature, Wet Bulb Temperature, Relative Humidity, Absolute Humidity, PPM, Thermocouple Surface Temperature | |
Ambient Temperature | Range | -30~120 Celsius degree (-22~248 Fahrenheit degree) |
Accuracy | ±0.4 Celsius degree (90~120 Celsius degree) ±0.2 Celsius degree (60~90 Celsius degree) ±0.1 Celsius degree (60~60 Celsius degree) ±0.2 Celsius degree (-30~20 Celsius degree) | |
Resolution | 0.01 (<100) 0.1 (Other) | |
Relative Humidity | Range | 0~100%RH |
Accuracy | ±1.5%RH (0~80%RH) ±2%RH (80~100%RH) | |
Resolution | 0.01 | |
Dew Point Temperature | Range | -45~120 Celsius degree (-49~248 Fahrenheit degree) |
Resolution | 0.01 (<100) 0.1 (Other) | |
Wet Bulb Temperature | Range | -20~40 Celsius degree (-4~104 Fahrenheit degree) |
Resolution | 0.01 (<100) 0.1 (Other) | |
Absolute Humidity | Range | 0-400g/m³ |
Resolution | 0.01 (<100) 0.1 (Other) | |
PPM | Range | 0~50000 |
Resolution | 1 | |
Thermocouple Surface Temperature | Type | K-Type |
Range | -50~200 Celsius degree (-58~392 Fahrenheit degree) | |
Accuracy | ±1 Celsius degree or ±1%Num (Take the larger value) | |
Resolution | 0.1 (<100) 1 (Other) | |
Temp. Unit | Celsius degree/Fahrenheit degree | |
Operating Conditions | Temperature | 0~50 Celsius degree (32~122 Fahrenheit degree) |
Humidity | 0~80%RH (No condensation) | |
Storage Conditions | Temperature | -10~60 Celsius degree (14~140 Fahrenheit degree) |
Humidity | 0~90%RH (No condensation) | |
Power Supply | 4Ã1.5V AAA(UM-4) Battery | |
Size | 205Ã80Ã31mm | |
Weight | 186g (Not Including Batteries) |
Main Unit | 1 |
TP-202 Surface Thermocouple (K-type, Ï14*230mm, -50~400 Celsius degree) | 1 |
Manual | 1 |
Carrying Case | 1 |
Note:
The default type of thermocouple in the standard accessories is K-type. If other types of thermocouple are needed, please specifying when placing order.
The warranty period is 12 months