Join today and be a part of the fastest growing B2B Network Join Now

AC drive for CT120 Mini economic inverters 1/3 phase 50/60Hz 220/380V

  • Origin: 43
  • Location: Shenzhen City (深圳市)
  • Supply Type: OEM service
  • Min Order: 1

Supplier Info.

  • Location Shenzhen City (深圳市)
  • Employees Total 51-100
  • Annual Revenue

AC drive for CT120 Mini economic inverters 1/3 se 50/60Hz 220/380V

Function Specification
I/O Features Input Voltage Range Single se 220VAC±20%; Three se 380VAC±20%
Input Frequency Rage 50?60Hz±5%
Output Valtage Rage 0?Rated input valtage
Output Frequency Rage 0?600HZ, unit: 0.01Hz
Output overload capacity 150% rated current for 60S?180% rated current for 10S?200% rated current for 1S
Control Function Control mode V/F control
Speed adjusting range Asynchronous motor 1:100
Speed control accuracy? ±0.5% (V/F control)
Speed fluctuation ±0.5% (V/F control)
Starting torque Asynchronous motor 0.5Hz/ 150%
Starting frequency 0.00?10.00Hz
0.1?3000.0s
Carrier wave frequency 1.0KHz ?16.0KHz
Frequency reference source UP/ DOWN input, digital setting, Analog setting, Multi-step speed setting, PID setting, MODBUS communication setting. Realize the shifting between the set combination and set channel.
Starting mode Frequency start, DC bracking
Halting mode Slow down halting, free halting, slow down halting+DC bracking
Energy consumption braking 320?750V
DC braking DC braking frequency?0?300HZ?
DC braking waiting time?0?50s?
DC braking current?0.0?100.0%?
DC braking time?0.0?50.0s?
Automatic voltage regulation (AVR) When the grid voltage fluctuates, changes in the output voltages is very small, remained constant V/F
I/O Terminals DI Terminals 5 channels common input
AI Terminals 1 channel analog inputI, AIN:0?10v or 0-20mA input optional
DO Terminal 1 channel multi-functional collector
Relay output Terminal 1 channel relay outpu
Communication Terminals RS485 communication interface Provide RS485 communication interface, adopt Modbus-RTU communication mode(RTU).
Fault protections Overcurrent?short circuit?overvoltage?Undervoltage?overheat?bus undervoltage?motor overload?Inverter overload?abnormal input power?abnormal output?outside fault?communication fault?current detection fault?motor self-learning fault?EEPROM operation fault?PID fault?braking fault,ect.
Man-machine interface LED Display Displayed related information in the high-lighted LED digital tube.
Environmental Constraint Installation sites Indoor. The inverter is prohibited to be stored at the place where with direct sunlight, fall of oil mist, steam, dust and with heavy oscillation.l
Temperature −10?+40??inverter will be derated if ambient temperature between 40?50??the rated output current should be reduced 1% if temperature rise every 1%
Humidity 5?95%, without condensation
Altitude 0?2000M?inverter will be derated if the altitude >1000M?the reted output cureent reduced 1% if the altitude rise 100M.
Oscillation <0.5g
Storage temperature −40?+70?
Premium Services
Need Buyers
Girl Right
Cross Popup
Arrow 2

I Am :

Signup today to claim your Discount. Get Started before it's too late!

Arrow 1
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Ok