Working Principle:This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.Technical Detail:
- Nominal Dia (mm) : 25 to 300 NB
- Material of Construction : MS, SS 304, SS 316 & SS 316L
- Electrode Material : SS 316, SS 316L, Hastelloy âcâ, & Tantalum
- Process Pressure : Max. 25 kg/cm2
- Process Temperature : Max. 150C
- Flow Tube Material : SS 316
- End Connection : Flange/Wafer
- Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
- Accuracy : ± 1% FSD Optional: ±0.5% FSD.
- Repeatability : 0.3% Display : 2 Numeric LCD Display Version : Integral /Remote
- Display Unit : Standard Unit in M3, Litre
- Power Supply : 230 VAC, 110 VAC & 24 VDC
- Output : Std. 4 â 20 mA
- Protection Class for Sensor : IP 65Protection Class for Transmitter : IP 65
- Cable Length for Remote : 10 meters
- Installation : Inge Type.
Application Areas:⢠STP (Sewage Treatment Plants)⢠ETP (Effluent Treatment Plants)⢠Chemical Industries⢠Food & Sugar Industries⢠rmaceutical Industries⢠Textile Industries⢠Ceramic Industries⢠Paper Mills⢠Industrial R.O.⢠Water supply schemes