HNAC Supply Secondary Electrical Service, Low Voltage Distribution System, Switchgear Power Systems For Sale

FOB Price: USD 1000 - 10000
|
- Sets (Min. Order)
  • Supplying Ability-
  • Supplying TypeOem service
  • Model Number-
  • Preferred Payment Method:L/C

Quick Details

  • Processing Time:1 set
  • Port:-
  • Supply Ability: -
  • Brand Name:-
Packaging & Delivery Packaging Details Package for switchgear power systems: 1, wooden case, standard package 2, Customized by clients' requirement Delivery Time Shipped in 30 days after payment HNAC supply secondary electrical service, low voltage distribution system, switchgear power systems for sale Product Description   Professional Medium voltage and Low voltage switchgear manufacturer in China Operating environment:  1)Ambient temperature:-5°C-+40°C;   2)Altitude: high voltage ≤1000Meter, low voltage ≤2000Meter (technical department will design specially if exceeds); 3)Relative humidity:≤85% 4)Seismic intensity:≤ magnitude 8; 5)Apply to the places have no fire,no explosion danger, no serious pollution,no chemical corrosion and no violent vibration. plc control cabinet Technical Parameter: 35KV high voltage switchgear power systems technical parameter: KYN61-40.5 Rated voltage kV 33~40.5KV Rated short time power frequency withstand voltage(1min) kV 95 Rated lighting impulse withstand voltage kV 185 Rated current A 1250,1600,2000 Rated short circuit breaking current kA 25       31.5 Rated peak value withstand current kA 63       80   24KV high voltage switchgear power systems technical parameter: KYN28A-24 Rated voltage kV 24~15KV Rated short time power frequency withstand voltage(1min) kV 65 Rated lighting impulse withstand voltage kV 125 Rated current A 630,1250,1600,2000,2500 Rated short circuit breaking current kA 25       31.5 Rated peak value withstand current kA 63       80   12KV high voltage switchgear power systems technical parameter: KYN28A-12 / XGN2-12 / HXGN-12 Rated voltage kV 3.6     7.2     12 Rated short time power frequency withstand voltage(1min) kV 24      32      42 Rated lighting impulse withstand voltage kV 40      60      75 Rated current A 630,1250,1600,2000,2500,3150,4000 Rated short circuit breaking current kA 20, 25, 31.5, 40, 50 Rated peak value withstand current kA 50, 63, 80, 100, 125   0.4KV low voltage switchgear power systems technical parameter: MNS / GCS / GGD Rated voltage V 400     690 Rated frequency Hz 50/60 Rated current A 400,500,630,800,1000,1250,1600,2000,2500,3150,4000,5000,6300