USER MANUAL
SNV-EKL3.2 Earth
fault and short circuit indicator
Description
SNV-EKL3.2 Earth fault and short circuit indicator,
it Widely used in various ring cabinets, high-voltage switch-gear and cable branch box in power system, can accurately and reliably detect the fault section and fault
type of power grid. The use of Earth fault and short
circuit indicator is an efficient
way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction,
photoelectric conversion, signal optical fiber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference
ability.
Equipped with fault remote transmission port, suitable for distribution network automation; Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the
whole machine is easy to load and unload.
Product Function
1) Intelligent detection of short-circuit and ground fault and through the corresponding LED indicator on the panel to indicate.
2)Display Monitor panel designed with
button, it is convenient for reset/or test.
3)It can set The pulse width time(Response time) of fault current for preventing incorrect fault indication caused by surge current.
4)It can set the reset time.
5)It can set the short circuit alarm
current via the Dip on short circuit sensor
6)It can set the earth fault alarm
current via the Dip on display unit monitor.
7)It can reset and detect the remote fault indication
device remotely.
8)It can provide switch volume for external devices
through remote relay contact.;
9)Remote fault indicating can be made by external
devices.;
10)Low battery display and alarm
Technology Parameter
Voltage grade
3-40.5KV
Battery life
≥8year
Frequency
50HZ/60HZ
Low voltage alarm of battery
≤2.7V
Short circuit alarm current
(7 levels)
200/250/300/400/500/600/1000A
Short circuit sensor fiber length
4meter, or customized
Earth fault alarm current
(6 levels)
10/20/30/40/50/60A ,or customized
Earth fault sensor cable length
5 meter,or customized
Reset time
(4 levels)
4H/8H/24/36H
Load fluctuation and escape pulse time setting
Short circuit
40/60/80/160ms
(4 levels)
Rated frequency withstand voltage
2KV/1min
Earth fault
Relay contact capacity
≤95W
work environment
Temperature
-40℃~+60℃
Alarm current accuracy
±10%
Humidity
≤95%RH
Working power
ER17505
battery
3.6V/3500mAh
Use for cable diameter
Short circuit CT
(Fiber, Type S)
A
Ф20mm~40mm,
Normally
B
Ф300mm~70mm customized
Working current
Standby state
≤10μA
Earth fault sensor
(Cable, type E)
A
Ф60mm~100mm
Normally
Working state
≤1mA
Indicator protection level
Monitor panel
IP 40
B
Ф80mm~130mm
Customized
Sensor CT
IP 67