GCAN-PLC New Original In Stock Modular Design Suitable For Various Industrial Sites

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability5000 Boxes Per Month
  • Supplying TypeIn stock
  • Model NumberGCAN-PLC-511
  • Preferred Payment Method:T/T, L/C, D/A, D/P, Western Union, Money Gram, PayPal, Other

Quick Details

  • Isolation level:Optocoupler isolation 500V
  • CAN open baud rate(bps):1000K,500K,250K,125K,100K,50K,10K
  • PDO mode:synchronization, looping,event-driven, polling
  • Bus terminal module quantity:up to 32 modules
  • Digital I/O signal:256 input/output
  • Analog I/O signal:64 input/output
  • Configuration mode:automatic configuration
  • PDO number (CAN open):4Tx/4Rx
  • CAN-Bus interface:one OPEN terminal interface,4Pin
  • Power:24V DC (-15%+20%)
  • Processing Time:7 days
  • Port:DALIAN
  • Supply Ability: 5000 Boxes Per Month
  • Place of Origin:China
  • Model Number:PLC-511
  • Brand Name:GCAN
  • Brand Name:GCAN
GCAN-PLC module is composed of a programmable control module (GCAN-PLC-400/510/511) and several I/O modules(GC-1008/2008/…). The control module has a variety of fieldbus communication interfaces that users can use to connect to the corresponding network and communicate with other devices. Without specialized downloader GCAN-PLC can use common micro usb to complete debugging and downloading 5 programming language Support SFC (Sequential function chart), LD (Ladder diagram), FBD (Function block), ST(Strutured text), IL (Instruction list) After-sales service 7 x24 hours every week after sales technical support with our professional engineers to solve problems GCAN-IO-8000/8100 —— with CANopen & Modbus communication protocol Performance CANopen adapter (GCAN-IO-8000) Modbus adapter (GCAN-IO-8100) Node number 1~127 1~247 Baud rate 10Kbps~1000Kbps 600bps~115200bps Power input 24V DC (18~36V) Insert I/O module number 32 pieces (at most 32*8 IO point) Dimension 100mm*69mm*48mm Working temperature, humdidness -40℃~+85℃, 0~90%RH, without condensation IP grade IP20 Module feature Standard CANopen slave station Support 4 TPDO, 4 RPDO Support 1 SDO, 1 emergency object, 1 node error control object Start to perdefine connection, suppor parameters store PDO mode supports synchronization, looping, event-driven, polling  Configuration mode is automatic configuration CAN interface: one open 4 terminal Input current, 70mA+ ( total GC-bus current), maximum 2.5A Starting current: about 2.5 times continuous current Power contacts: maximum 24V DC/maximum 10A Electrical isolation: 1500 Vrms Support standard Modbus protocol, a standard Modus slave station Support Modbus function code:01, 02, 03, 04, 05, 06, 15, 16 Support CRC validation Support Modbus TCP, Modbus RTU communication (corresponding to two kinds of style) RS485 interface adopts standard two-wires system Serial interface baud rate supports 600bps~115200bps, configured by serial interface The maximum number of bus terminals module is 64 Configuration mode is automatic configuration, expandedfreely Ethernet interface supports static or dynamic IP acquisition Ethernet interface supports heartbeat and timeout disconnection Ethernetwork interface is fixed, target IP and target interface can be set Automatic restoration of connection resources after the Ethernet interface is disconnected,and reliable establishment of TCP connections Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,UDP, etc.). The upper computer communication software complies with the standard SOCKET rules. Input current, 70mA+ (total GC-bus current), maximum 4500mA Starting current: about 2.5 times continuous current Power contacts: maximum 24V DC/maximum 10A Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage) Standard DIN rail,designed for industrial design