Quick Details
- voltage:10kv
- indoor:50hz
- Processing Time:-
- Port:shenzhen
- Supply Ability: -
- Brand Name:sanhe
- Model Number:hvca
- Place of Origin:shenzhen
- Brand Name:sanhe
HVCA is widely used in power system, industrial and mining enterprises distribution network. In order to improve power factor, reduce line loss, and improve voltage
quality of system, it achieves the synthetically automatic control of reactive power and voltage by setting capacitor group mode ,automatically switching compensation capacitor and regulating
on-load tap changing transformer according to the demand of reactive power.
Feature
Equipped with high-tech power factor controller to detect the reactive power and finally to switch on/off in minimum times. The controller can be remote controlled by connecting with computer.
The parameters can be transferred to computer by communication port(485).
Optimizing and matching capacitor group and reactor parameters, which can effectively suppress inrush phenomenon and high harmonic.
Adopting special vacuum contactor of switching capacitor group, suitable for frequently switching, no resignation, no bouncing.
The ejecting fuse and relay protection, protection of the overvoltage, under voltage, over current, instantaneous current, open delta voltage and fault locking, which ensure safe operation of the
device.
Equipped with high voltage display device, magnetic lock and observation window. Force locking function to keep the operator safe.
Working Conditions:
Installation site: indoor, outdoor;
Environment temperature: - 25 ºC ~ + 40ºC;
Air relative humidity:≤ 95%
Height:≤ 1000 m;
Seismic capability: 8 magnitude earthquake;
Work location: ground inclination is not more than 5 degree;
Environment: no fire, explosion danger, chemical corrosion gas and violent vibration places.
Multifunction Performance
The isolator switch is
mechanical manual operation type which can open a obvious gap to keep operator safe while off-power maintenance.
The series reactor of
6% detuning factor can limit inrush current and 5 times or above 5 times harmonics.
The discharge coil and voltage reply can
provide protection signal of open triangle unbalance.
The current transformer and current relay work
for overcurrent protection.
The Zinc Oxidation Arrester works for absorbing overvoltage
The monitor and magnetic lock protect operator
safe by forcing locking.
The humidity controller can automatically
control heater and cooling fan to adjust cabinet inner environment.
The panel has functions of short-circuit
protection,operation overvoltage protection(arrester),over-current, open triangle unbalance voltage(relay). The others are realized by your superior switchgear.
Test before
delivery
Appearance inspection
electric clearance
creepage distance
Capacitance measurement
Power frequency
voltage withstanding test
Protection equipment test
sea-freight packaging and container
Project introduction
This is Chinaautomatic parking system factory factory project. In 2014, we supplied 2200kVAR automatic reactive power correction installations. And we also commissioned them in the project
site.