Dioxin Stack Sampler

FOB Price: USD 0 - 1400
|
- (Min. Order)
  • Supplying Ability- Per Week
  • Supplying TypeOem service
  • Model NumberTG-002
  • Preferred Payment Method:T/T, Other

Technogroovy

India

Port: by road

Quick Details

  • Processing Time:3 days
  • Port:by road
  • Supply Ability: - Per Week
  • Brand Name:Technogroovy
Dioxine Stack Sampler Gaseous and particulate are dynamically removed from the emission source and collected in a multi-component sampling train. The group's components consist of a fiberglass filter and two sets of glassware called the front half and the back half.The front half consists of a group of glass nozzles, a probe covered with heated glass, the front half of the filter holder with the filter.The back half includes a back half filter stand, insulated PTFE sample transfer tube, condenser coil and solid absorbent unit. Technogroovy Dioxine Stack Sampler  contains all the components required to form the back half of the assembly equipment. Technogroovy manufactures all components of the front half glassware, including the glass openings, the heated glass-lined probe (, the heated filter box, and the insulated PTFE sample transport tube). Technogroovy also makes the entire stand holder and also supplies the filter. Technical Specifications:   Stack Temperature Range  : Ambient to 600 deg C read on a Digital Pyrometer. Stack Velocity Range  : 3 to 60 m/sec  Thermocouple            : T/C sensor in SS 304 casing, length of      insertion: 1 m with 2m long cable. Manometer                  : Digital with 0-1300 mm of H2O range Pitot Tube                   : Calibrated S-type fabricated -SS 304, 1m long Particulate Sampling   : 0 -60  lpm collection on thimble type filter up to 0.3 micron rating. Gaseous Sampling       : 0 - 3 lpm collection in a set of Borosilicate glass impingers. Rotameter                   : Acrylic body with 5% FSD accuracy, 0 - 30 lpm for PM and 0-3 lpm for GAS. Sampling Probe           : 1m long SS tube with inside lining of Teflon & provision for controlled at 120 deg C heating. Filter Holder               : Glass filter holder with heating provision Digital Clock               : 0-60 minutes, 1 second readout with start and stop switches. Temp. Controller         : Digital type temperature controller. Dry Gas Meter            : Range 0 to 40 LPM connected to SPM line. Sampling Train            : 3 Nos. of 240 ml cap glass impinger, 1 No. condenser glass coil, 1 No. moisture bottle 400 ml & 1 No. cartridge tube accommodated in separate ice tray with instrument panel with a provision to cool down flue gas temperature. Vacuum Pump            : Mono block Rotary Vane type, oil free, 0.5 HP single phase motor (230V) with more than 100 lpm free flow capacity.   List of Components : (1) :Instrument panel consisting of pyrometer, manometer rotameters, vacuum gauge, stop watch, dry gas meter & temperature controller.  (2): Probe kit consisting of probe pipe, pitot tube, connecting hoses, tool kit, filter holder, nozzles, thermocouple, heating system, tripod etc.  (3): Cold box assembly consisting of glass impingers, condenser glass coil, moisture bottle & water pump.  (4): Vacuum pump assembly.

You May Be Intrested In