Quick Details
- Product name:Vortex flow meter
- Diameter:15mm-200mm
- Output:4-20mA, pulse, Hart, RS485
- Power supply:24VDC, 3.6V
- Nominal pressure:1.6mpa 2.5mpa 4.0mpa 6.3mpa
- Installation type:Flange, Tri-clamp, Inserted
- Body material:SS304, SS316
- Accuracy:0.5%, 1.0%
- Protection level:IP65 IP67 IP68
- Repeatability:0.3%
- Processing Time:7-30
- Port:shanghai/qingdao/tianjin/guangzhou
- Supply Ability: 5000 Sets Per Month
- Brand Name:Philemon
Application
Vortex flow meter is used to meausre kinds of steam, gas, air and low viscosity liquid.
Introduction
According to Carmen and Strouhal relevant spiral produce and on the theory of the flow relationship. As shown in picture, In the meter body vertical insert a triangular prism root namely the
happening of the body, when eddies of medium flow through the table body, in triangular prism behind the alternate produce in opposite directions regular karman swirl,its spiral separation and
the flow of the medium frequency F speed by sensing head is proportional to the V detected the number of spiral,can measure the flow velocity,again according tp the table body mouth.
Features
Flange&body: integrally forged pieces, it will avoid break down into pieces. 100% SS304 material,we can provide material report.
Circuit Board: Digital circuit board,anti most of the supplier use analog circuit board,digital circuit board enjoy the advantages of anti-vibration and anti-interference.
Flow converter: Distinctive modular design, amateurs can operate, disassemble and assemble easily, it will avoid accident risks.
Welding: adopt the advanced fish scale technology,which makes the welding seam looks nice and smooth.
Japan OVAL technology with embedded-type sensor, triangular prism will not fall off, we already apply for patent.
Our medium temperature sensor can measure highest temperature around 350℃,normal it is -40~250℃
Nominal
diameter
DN(mm)
Liquid(t=20℃ ρo=1000Kg/m3)
Gas(t=20℃ 101325 Pa Air)
Standard Range
Obtained Flow Range
Standard Range
Obtained Flow Range
20
1~8
0.6~12
5~50
5~60
25
1.5~12
0.8~16
8~80
8~120
40
2.5~30
1.5~40
20~200
18~300
50
3~50
2~60
30~300
30~500
65
5~80
3~90
50~500
50~900
80
8~120
5~150
80~1000
60~1200
100
12~200
6~240
100~1000
100~2000
125
20~300
13~390
150~1600
150~3000
150
30~400
15~600
250~2500
200~4000
200
40~800
30~1200
400~4000
350~8000
250
80~1200
40~1600
600~6000
500~12000
300
100~1800
1000~10000
1000~10000
600~18000
The size of stress type vortex sensor as follows:
Table 1:Connection mode
Connection
mode
Flange
connection type
Flange card
installed type
inserted type
others
Mark No
1
2
3
4
Table 2:Measured medium
Measured
medium
Liquid
common
gas
saturated
stream
superheated
steam
others
Mark No
1
2
3
4
5
Table 3:Caliber
Flange connection type,Flange card installed type
Caliber
15
20
25
32
40
50
65
80
100
125
150
200
250
300
Mark No
150
200
250
320
400
500
650
800
101
125
151
201
251
301
Insreted type
Caliber
100
125
150
200
250
300
350
400
500
600
700
800
900
1000
1200
1400
1600
1800
2000
Mark no
10
125
151
201
251
301
351
401
501
601
701
801
901
102
122
142
162
182
202
Table 4:special mark
Format
Common
standard
signal
output
Intrinsically safe
explosion-proof
Scene
shows
high
temperature
temperature
compensation
pressure
compens
ation
Temperatu
re-pressur
e compens
ation
Mark No
Mo mark
M
B
X
G
W
Y
Z