Quick Details
- HM:Trouch panel
- Power factor:0.93
- efficiency:90%
- Protection type:Over voltage,over heat
- cooling method:Water cooled, forced air cooled
- Remote control:MODBUS, Profinet, Profibus
- Processing Time:6-8 weeks
- Port:Shanghai,Tianjing
- Supply Ability: 5000 Sets Per Month
- Application:Battery charging
- Brand Name:Green Power
- Place of Origin:China
- Type:Single
- Brand Name:Green Power
1. Application
15v acdc switching power supply is aplied to:
Electrochemistry: Plating, anodizing, electro polishing, electrolysis, electro winning, electro refining, electronic cleaning,
tinning, pickling, surface coloring, cathod protection
Heating: Inductive heating, DC heating, single phase AC heating
Water treatment: Waste water treatment, seawater desalination
Battery charging: Battery charging
2. Product basic introduction
This rectifier is suitable for battery charging to provide stable DC power supply.
This rectifier adopts high frequency IGBT as semiconductor component and PWM modulation technology. It is modular structure design, easy to expand output current capacity, several rectifier
modules could be connected in parallel and mounted in stack up to 20 modules to make more current. Single rectifier has independent power modules, each module could output independently or output
in parallel connection.
The rectifier is made up with the following subassemblies:
Diode bridge
IGBT inverter H bridge
High frequency transformer
Secondary Schottky diodes
Capacitors and inductors
Control and protection circuit and devices
Cooling circuit
Remote control box(optional)
3. Comparison with other suppliers
1. Rectifier status indication
(1) Auto/Manual mode display
At left it is Auto mode, at right it is Manual mode
Auto mode: ; Manual mode:
(2) CC/CV mode
At left it is CC mode, at right it is CV mode
(3) Charging status
When the rectifier is charging battery, the red light is on. When it is not charging, the color is grey.
(4) Charged status
When the rectifier finishes charging, the red light is on. Otherwise, the color is grey.
(5) Alarm status
When there is no alarm, it shows red color continuously, when there is alarm, it is flashing.
(6) Cell number
It shows number of series connected cells.
(7) Status:
l It shows the status of the rectifier, including:
Charging, charged, stop.
l When there is fault with battery, it will show battery status, including:
When actual battery voltage exceeds set max. Voltage*cell number, it will show incorrect battery voltage.
When actual battery voltage is lower than set min. Voltage*cell number, it will show no battery.
The min. and max. voltage is set on touch panel parameter setting page.