Diesel Generators Battery Charges

FOB Price: Get Latest Price
|
- (Min. Order)
  • Supplying Ability10000 Units Per Week
  • Supplying TypeOem service
  • Model NumberEN 24/10 amp
  • Preferred Payment Method:PayPal, Other

ENERMAX SYSTEMS

India

Port: MUMBAI

Quick Details

  • Processing Time:5 WORKING DAYS
  • Port:MUMBAI
  • Supply Ability: 10000 Units Per Week
  • Brand Name:dg set battery chargers
  • Frequency:1-100
  • Model Number:en24/10
  • Output Type:10 amp
  • Place of Origin:in house
  • Rated Current:24 amp
  • Rated Power:230 w
  • Rated Voltage:24
  • Brand Name:enermax
BATTERY CHARGER FOR Diesel Generator SETS. These battery chargers are specially designed for Diesel Generators / Engine Start applications taking specific requirements into consideration. These are based on SMPS technology adopting latest Pulse Width Modulation Technique.   Various available ranges are as follows. 1.     12 Volts, 6 Amps: Suitable for Single Battery up to 100 Ah capacities. 2.     12 Volts, 10 Amps: Suitable for Single Battery above 100 Ah up to 200 Ah capacities. 3.     24 Volts, 10 Amps: Suitable for Two Batteries in Series up to 100 Ah each Battery capacity. Other Non-standard ranges like 24 Volts, 20 Amps (Suitable for Two Batteries in Series above 100 Ah up to 200 Ah each Battery capacity) also can be made available against specific request. THE COMPANY: Company with more than 20 years of Experience in switching power supplies and charger. Manufactured in a state of the art ISO – 9001:2015 Facility. Highly qualified & experienced R&D team. Technical Specifications Electrical Characteristics’ 24V, 10A 12V, 10A 12V, 6A 1. Input Voltage 170 – 300V AC 170 – 300V AC 150 – 300V AC 2. Output Voltage-Boost mode 27.4 – 28V DC 14V DC 14V DC 3. Output Voltage-Float mode 26.2 V DC 13.4V DC 13.4V DC 4. Charging Current-Boost mode 10A 10A 6A 5. Charging Current-Float mode 0 – 4A 0 – 4A 0 – 2.5A 6. Leakage Current @ 230 V ac < 2mA < 2mA < 2mA 7. Line regulation < 1% < 1% < 1% 8. Load regulation < 1% < 1% < 1% 9. Ripple content 150mV p-p 150mV p-p 150mV p-p 10. Dielectric strength:       i. Between Input & Output 2 kV AC 2kV AC 2kV AC ii. Between Input & Earth 1.5kV AC 1.5kV AC 1.5kV AC iii. Between Output & Earth 1.5kV AC 1.5kV AC 1.5kV AC   Protections   1.       In rush current 2.       Over voltage at Input 3.       Under voltage at Input Limited by NTC Thermister Shut down above 300V AC Cutoff at 140V AC. Cut in at 160V AC   4. Over voltage at Output 29.5V                               15.5V 15.5V 5. Short circuit at Output Protected                      Protected Protected 6. Overload at Output Protected                      Protected Protected 7. Reverse polarity of Battery Protected                      Protected Protected 8. Over voltage due to external source Protected                      Protected Protected   Other Features   1.       Indications                                                          Mains ON, Boost mode, Float mode, Battery Reverse 2.       Annunciation                                                     Potential free NO/NC contact for Charger ON/FAIL   Mechanical   1. Type of mounting                                                Wall mounting Type   2. Dimensions WxDxH 195x127x94 185x125x65 175x115x60 3. Weight (Approx.) 1500g 1200g 1000g   Environmental   1.       Operating Temperature                                0 – 50 Deg.C 2.       Operating Relative Humidity                       0 – 80% Max. 3.       Vibrations                                                           10 – 500Hz 2G-10min. / 1 Cycle 60 min. along all three axes