Quick Details
- Processing Time:-
- Port:-
- Supply Ability: 1000 Sets Per Month
- Brand Name:Nantianya
GCK Low-voltage Withdrawable Switchgear
Overview
The GCK series
switchgear consists of a power distribution center (PC) cabinet and a motor control center (MCC) cabinet. Applicable to power users such as power plants, substations, industrial and mining
enterprises, etc. as a power distribution system with 50 Hz AC, maximum working voltage to 660V, and maximum working current to 3150A, as power conversion for power distribution, motor control
and lighting. For distribution control purposes. The product has high breaking capacity, good dynamic thermal stability, advanced and reasonable structure, practical and practical electrical
scheme, strong series and versatility, and any combination of various scheme units. The cabinets contain more circuits and save land. The area, the appearance is beautiful, the protection level
is high, the safety is reliable, and the maintenance is convenient. Product
StandardsThe product complies
with IEC60439 standard, and also meets the national standard GB7251-87 "Low-voltage switchgear" and ZBK36001-89 "Low-voltage withdrawable switchgear" standard. Product
model and its meaning
The
main technical parameters
Structural
featuresThe basic cabinets of
GCK and GCL are assembled and assembled. All the structural parts of the cabinets are galvanized and spray-coated. They are connected to each other by screw fastening to form a basic cabinet
frame. Then, as required, doors, baffles and partitions are added. The drawers, mounting brackets, and busbars and electrical components are assembled into a complete control center cabinet. The
cabinet structure has the following features. Cabinet
The frame
is made of special-shaped steel, which is positioned by gussets and bolted with no welded structure.
a. The
molding size of the parts, the opening size, and the device spacing are modularized. (modulus E = 20 m m, the same below).
b. Internal
structural parts are galvanized.
c. External
phosphating; then electrostatic epoxy powder coating.
d. The
cabinet is divided into three separate sections: busbar, functional unit and cable, which can prevent accidents from spreading and facilitate electrification. The frame is made of profiled steel,
with gusset positioning and bolted joints without welding.
a. The
molding size of the parts, the opening size, and the device spacing are modularized. (modulus E = 20mm, the same below).
b. Internal
structural parts are galvanized.
c. External
phosphating; then electrostatic epoxy powder coating.
d. The
cabinet is divided into three separate sections of busbar, functional unit and cable to prevent accident spread and easy to charge the functional unit (drawer part)
a.
Functional unit: feed unit, motor unit, utility power unit.
b. The
drawer module has a height modulus of 200mm and is divided into five series of sub-units, 1 unit, sub-unit, 2 unit and 3 units. The unit circuit is rated at 630A or below.
c. Each MCC
cabinet can be installed with up to 9 one-unit drawers or 18 one-unit drawers.
d. The door
panel of the compartment is mechanically interlocked with the drawer by the operating mechanism of the main switch. When the main switch is in the closing position, the door panel cannot be
opened.
e. The
operating mechanism of the main switch can be locked in the closing or opening position with a shackle, which can safely repair the electrical equipment.
f. The
functional unit compartments are separated by a metal partition.
g. The
shutter in the compartment is automatically opened and closed as the drawer is pushed and pulled out so that the vertical busbar is not accessible in the compartment.
Structural
characteristics
1. The
basic skeleton of the switchgear is a combined assembly structure. The whole structure of the cabinet frame is made by self-tapping screws, and the door, partition, sealing plate, bracket and
busbar, drawer and electrical components are complete. Switch cabinet. Since the original GCKI skeleton adopts the GF28 profile, the profile steel plate is thinner, and in addition, when the
profile is galvanized, a part of the interior has a dead angle, so that the service life of the cabinet is greatly shortened. At the same time, factors such as the standardization of its overall
structure are taken into consideration. Our company boldly improved. Type C special profiles are used. It is made of 25mm modulus and 2mm thick steel plate. It is reinforced with self-tapping
screws with strong rigidity during assembly, which makes the combination more flexible and convenient, and the service life is longer.
2. The
switch cabinet adopts modular design and divides the cabinet into three zones. The top is the busbar area, the front is the electrical area, the rear is the cable outlet area, and the electrical
and cable areas are separated by steel plates.
To ensure
the normal operation of the line. Effectively prevent the fault from expanding. When the electrical components are pulled out of the cabinet, the charged body in the cabinet is not exposed. For
the user, the use is safer and more reliable. For the feeder cabinet. The cabinet is 600mm wide. Up to 9 or 18 feed circuits can be installed. (18 feeder circuits are only suitable for load units
with capacities below 63A)
3.
According to the characteristics of the switchgear, it can be divided into power receiving cabinet, PC cabinet (power center), MCC cabinet (motor control center) and capacitor compensation
cabinet.
4. The
drawers of the same functional unit can be interchanged. Once the fault occurs, the unit is pulled out and the spare drawer is inserted, and the power can be sent. This greatly shortens the power
failure time due to the fault and improves the reliability of the equipment.
5. The
switch cabinet can be designed as a hybrid cabinet and a drawer cabinet. It can also be a drawer type that retains the simplicity, practicality and low cost of the fixed cabinet, and has the
advantages of small volume, strong function and easy replacement.
6. In order
to ensure the personal safety of the operating procedures and maintenance personnel, a mechanical interlocking mechanism is arranged in the switch cabinet, and a mechanical interlocking mechanism
is arranged in the drawer unit and the door and the main switch. Make it use more
7. The
height of the drawer of the switch cabinet is divided into four standard sizes, namely: 1 unit/2, 1 unit, 2 units, 3 units, which is light in structure, convenient in assembly, reasonable in
layout, and has three positions of work, test and isolation.
8. The N
and PE wires of the switchgear are at the lower rear of the switchgear, and the PE wire is connected with the cabinet frame, which not only makes the outlet cable connection more convenient. And
the grounding is more reliable.
9. The
ventilation system is provided at the top of the switchgear and the upper and lower ventilating doors without reducing the degree of protection.
■
shape and installation size
1.
Dimensions
■Normal
use of environmental conditionsThe altitude should not
exceed 2000m. The ambient air temperature is not higher than +409C, and the average temperature is not higher than +35 °C within 24h, and the ambient air temperature is not lower than -5 °C.
Atmospheric conditions: air is clean, relative humidity does not exceed 50% at +40 °C, and higher relative humidity is allowed at lower temperatures. For example, 90% at +20 °C, no fire,
explosion hazard, serious A place where pollution, chemical corrosion and severe vibrations occur. It is inclined no more than 5° from the vertical plane. The control center is adapted to the
following temperature transport and storage processes, -25 ° C - +55 ° C, in a short time (not more than 24 h) does not exceed +70 ° C. If the above conditions of use cannot be met, the user
shall submit it to our company at the time of ordering and resolve it by negotiation. The installation of the GCK series switchgear is not vertically installed on the wall, and the rear is the
outlet cable trench of the cabinet. For maintenance, the rear wall is usually 1000-1200mm.