Quick Details
- Processing Time:7-30 DAYS
- Port:-
- Supply Ability: -
- Brand Name:-
Overview
EM-5 series flue gas analyzer is a series of self-developed gas analysis products for
online gas analysis of domestic as well as foreign environmental protection and industrial control. Based on UV Differential
Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features
of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control,
safety monitoring and etc.
Depended on years of flue gas analyzer research experience and combined with practical experience
of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index
requirements in different working condition.
UV DOAS technology. The optical technology platform consists of a light source, gas chamber,
optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.
Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed
by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into
spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.
The corresponding component concentration in the gas can be calculated by analyzing the
spectrum.
Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the
different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure
with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.
Features Of EM-5 online gas analyzer High measurement accuracy
Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)
Ultraviolet has no moisture absorption, undisturbed by moisture and dust
No cross interference between measured gases ( refer to table 1)
Measure NO and NO2 simultaneously without converter
Low detection limit
Measuring gas
Interference
SO2
NO
NO2
O2
SO2 (500ppm)
/
<1ppm
no
no
NO (500ppm)
no
/
no
no
NO2 (500ppm)
no
<1ppm
/
no
H2O (no dew)
no
no
no
no
CO (1000ppm)
no
no
no
no
CO2 (20%)
no
no
no
no
O2 (21%)
no
no
no
/
High reliability
Small zero drift and span drift
Modular design
No optical moving parts, without vibration influence
Strong gas chamber, low cost
Automatic adjustment spectrum technology, long maintenance-free period
Adopt pulse light source with 10-year service life
Technical Parameter Of EM-5 Flue Gas Analyzer
Measurement Principle
UV-DOAS+PLS
Versions
Regular range
Low range
Ultra-low range
Ranges
My range
Max range
My range
Max range
My range
Max range
Component
SO2
0-300ppm
0-3000ppm
0-100ppm
0-300ppm
0-50ppm
0-100ppm
NO
0-300ppm
0-3000ppm
0-100ppm
0-300ppm
0-50ppm
0-100ppm
NO2
0-500ppm
0-4000pp
0-300ppm
0-1000ppm
0-100ppm
0-200ppm
O2 (ECD or ZrO2)
0-5%
0-25%
0-5%
0-25%
0-5%
0-25%
Linearity
≤±3%F.S.
Repeatability
≤2%
Zero Drift
≤ ± 2% FS / 7d
Span Drift
≤ ± 2% FS / 7d
Response Time(T90)
≤50s
Working Temperature
-20 ℃ ~ + 50 ℃
Preheating Time
No preheating
20min
40min
Sample Gas Interface
Φ6 Bi-Lok
Sample Gas Flow
Range: (0.5 ~ 2) L / min, fluctuation < 25%
Sample Gas Pressure
Current ambient pressure ±0.1Bar
Sample Gas Temp.
0 ℃ ~ + 50 ℃
Sample Gas Humidity
No condensation (under sample gas temperature)
4-20mA Input
3 , configurable, 100Ω load
4-20mA Output
5, output content can be configured, maximum load capacity ≤800Ω
Switching value Input
6 , configurable
Relay Output
14, output content can be configured. DC30V2A
Digital I / O
1×Rs232, 1×Rs485 (Support Modbus protocol)
Installation Method
19’ panel
Supply Voltage
220VAC ± 10%
Rated Power
About 100W
About 120W
Application Of EM-5 Flue Gas Analyzer
Coal-fired power plantCement plantIndustrial furnaceDeSOX process monitoringDeNOX process monitoringWaste incineration plantPVC
process in chlor-alkali plantTitanium dioxide production processSulfur recovery processNatural gas purification processMethyl iodide analysis for the coal chemical industry On-line air monitoring
Hangzhou Zetian Technology is committed to the integrity, strength and quality of our
air quality monitor. We're internationally recognized. We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please contact us!